U3 ICC Tank Tightness Testing/ Certified Exam Q&A/ 2025.Terms in this set (63) On a steel tank without cathodic protection, if a coating is flawed, what happens at the flaw?

  • Cathodic surface is
  • increased

  • Current flow is
  • increased from this area

  • Current flow is
  • increased to this area

  • Current flow is increased from this area
  • On an impressed current cathodic protection system, the negative wire of the rectifier is

connected to the:

  • Anode
  • Cathode
  • Drop tube
  • Dielectric union
  • Cathode 1 / 3

All are examples of acceptable release detection for tanks,

except:

  • Impressed current
  • cathodic protection

  • Automatic tank gauging
  • Statistical inventory
  • reconciliation

  • Soil-vapor monitoring
  • Impressed current cathodic protection
  • When a tank is temporarily closed, the cathodic

protection system:

  • Must be turned off
  • Must remain in
  • operation

  • Should be removed
  • Operator can have it on
  • or off.

  • Must remain in operation
  • When a steel tank is installed with a galvanic CP system attached, the tank gauges are usually connected through a riser with a dielectric bushing.What is the purpose of that?

  • To prevent static
  • discharge

  • To minimize effects of
  • noise

  • To electrically isolate
  • the tank from the tank gauge

  • To prevent water
  • intrusion in the tank

  • To electrically isolate the tank from the tank gauge 2 / 3

Factory-installed diectric coatings may include all of

the following except:

a . Asphalt

  • epoxies
  • Enamels
  • fiberglass-reinforced
  • plastic a . Asphalt According to the EPA, Tank tightness test data

must be maintained for:

  • 18 months
  • 3 years
  • 5 years
  • Until the next test is
  • performed

  • Until the next test is performed
  • How long must records of UST system repairs be available on site?

  • 60 days
  • 1 year
  • 5 years
  • for the remaining
  • lifetime of the UST system

  • for the remaining lifetime of the UST system
  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 1, 2025
Description:

U3 ICC Tank Tightness Testing/ Certified Exam Q&A/ 2025. Terms in this set On a steel tank without cathodic protection, if a coating is flawed, what happens at the flaw? a. Cathodic surface is incr...

Get this document $30.00