When the required minimum clearance for a vent connector is 9" (228 mm) to combustible material with no protection, what is the acceptable method to reduce the clearance by 3" (76 mm)?
- use 0.05" (12 mm) insulating millboard spaced out 0.05 (12 mm) with
- use 0.25" (6 mm) insulating millboard spaced out 1" (25 mm)
- use 22 gauge sheet metal attached to the hot side of the-combustible
- use 28 gauge sheet metal spaced out 1" (25 mm) from the
noncombustible spacers
material
combustible material - ANSWER-B
When using a gas detector such as a Drager or Gas Tec type, the most
important aspect regarding the sample tube is that the:
- detector is within the manufacturer's date code
- sample tube is within the manufacturer's date code
- detector has been inspected and verified
- the sample tube is CGA approved - ANSWER-B 1 / 4
Page 2 of 132
How far above the burner port does the centre line of the flue outlet have to be to convert a revertible flue furnace with a natural draft burner?
- at least 6" (150 mm)
- less than 12" (300 mm)
- at least 12" (300 mm)
- at least 24" (600 mm) - ANSWER-C
The vent of a direct vent propane appliance shall not terminate:
- Within 2 ft. of a property line
- Less than 3 ft. from a gas service regulator
- Within 3 ft. of a mechanical air supply inlet to a building
- Within 10 ft. of a mechanical air supply inlet to a building - ANSWER-
C
Which of the following is the best way to increase the furnace blower speed?
- Open up the motor pulley
- Close up the motor pulley
- Install a higher horsepower fan motor
- Increase the size of the return air duct - ANSWER-B 2 / 4
Page 3 of 132
The baffles in a hot water boiler
- To reduce water flow
- Clean boiler tubes
- Premix air and gas
- Slow hot flue gases flow - ANSWER-D
A condensing furnace has:
- One heat exchanger
- Operates without a heat exchanger
- Two heat exchangers
- Condensate drain and one exchanger - ANSWER-C
Before lighting a burner in a steam boiler, ensure that:
- there is water in the boiler
- the temperature controller is set properly
- the main burner test firing valve is turned on
- the safety valves are open - ANSWER-A
On seasonal start up, a pool heater should run:
- intermittently 3 / 4
Page 4 of 132
- continuously for 24 hours
- continuously until the thermostat is satisfied
- one hour on and one hour off until the thermostat is satisfied -
ANSWER-C
Steel boilers are generally classified as:
- Water tube boilers
- Vapour tube boilers
- Square sectional boilers
- Oval Sectional boilers - ANSWER-A
Expansion tanks provide a place for:
- Water to cool before returning to the system and pressure to build so
- Hot water to expand so it will be forced through the system and for
- Water to travel and allow for pressure fluctuations in the system
- Condensate to collect before it returns to the boiler and a place for
the system will operate properly
steam to be trapped
steam to expand in the system - ANSWER-C
The device that the water tank uses to direct the incoming water to the lower part of the tank is called?
- / 4