TEXAS WASTEWATER CLA SS A 200

Study Guides Aug 16, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

  • | Page

TEXAS WASTEWATER CLA SS A | 200

QUESTIONS WITH 100% CORRECT

ANSWERS | VERIFIED | LATEST

UPDATE

Question :Seeding of BOD samples is necessary when

samples (All of the above) have a chlorine residual, have a previously been chlorinated, have been subjected to high temperatures, contain high or low pH industrial wastes

Correct answer:(All of the above)

Question :Why is recirculation needed in a trickling filter?

Keep the media wet Further reduce BOD All of the above (a, b, and c)

Correct answer:All of the above (a, b, and c)

Question :What type of fire extinguisher would be used on an

electrical control panel that has been de-energized?Class A Class C (a and d)

  • | Page

Correct answer:(a and d)

Question :What is eutrophication in a pond system?

Enrichment with nitrogen and phosphorous Causes algae blooms (b and c)

Correct answer:(b and c)

Question :Carbon monoxide (CO) poisoning symptoms are

tightness in the chest nausea drowsiness and headache (all of the above)

Correct answer:(all of the above)

Question :Dangerous gases in a confined space may not be

detected with the physical senses because some gases have no odor some gases may deaden the sense of smell some gases may displace the oxygen (all of the above)

Correct answer:(all of the above)

Question :What are the dangerous gases a collection system

worker might come into contact with?

  • | Page

CO2 CO НaS CH4 (all of the above)

Correct answer:(all of the above)

Question :Monitoring and reporting records of a wastewater

treatment plant shall be kept at the facility site for a period of

  • three years

Correct answer:d. three years

Question :The TCEQ Design Criteria requires that deflection

tests be performed on all new installed flexible or semi-rigid pipe after the final backfill has been in place for 30 days. This deflection test is usually performed using a rigid ball or mandrel that has a diameter equal to -percent of the inside diameter of the pipe.

  • 95

Correct answer:c. 95

Question :Seeding of BOD samples is necessary when

samples

  • all of the above
  • | Page

Correct answer:e. all of the above

Question :What is the purpose of biomonitoring of a plant's

effluent?

  • Test for toxicity

Correct answer:d. Test for toxicity

Question :In an anaerobic digester, the percentage of methane

and carbon dioxide gas content should be

  • 70% methane, 30% carbon dioxide

Correct answer:b. 70% methane, 30% carbon dioxide

Question :The sludge from a primary clarifier should contain

what percent solids?

  • 4% to 6%

Correct answer:b. 4% to 6%

Question :What is the standard chlorine residual and contact

time on Texas discharge permits?

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 16, 2025
Description:

TEXAS WASTEWATER CLA SS A | 200 QUESTIONS WITH 100% CORRECT ANSWERS | VERIFIED | LATEST UPDATE Question :Seeding of BOD samples is necessary when samples (All of the above) have a chlorine residual...

Get this document $30.00