ICC California UST (Underground Storage Tank) Service Technician Exam includes accurate and verified questions covering California-specific UST regulations, system components, installation and maintenance procedures, leak detection, monitoring systems, and safety protocols. This exam is required for technicians seeking certification to perform installation, inspection, and servicing of UST systems in California.

The written report submitted to the local agency after an unauthorized release is required to include the following

EXCEPT:

Cause of release

An unauthorized release which does not escape secondary containment, requires only recordation on the Operators Manual Report provided if what criteria is met?It did not cause deterioration of secondary containment. It did not increase the hazard of fire. It was cleaned up within eight hours and it was cleaned up within eight hours detection.

  • / 4

2

Recording of an authorized release in the operators monitoring records shall include?Actions taken to prevent further releases.

If a authorized release meets reporting requirements of Title 23, section 2652, the report must be filed within the? (Un or A?)

Local agency

Which statement concerning the annual monitor certification is most correct?

Local agencies must be notified 48 hours prior to certification in results must be submitted within 30 days of certification.

The annual monitor certification may be performed by? 2 / 4

3

A person possessing the appropriate contractor's license. An individual trained and certified by the manufacture of the monitoring equipment.

The following is true of secondary containment EXCEPT:

Must be tested every 24 months.

Enhanced the detections results must be submitted to ___ within ___days the local agency and state water resources control board within 60 days.

The EPA recommends that monthly the operator should conduct

a walk-through inspection of the following EXCEPT: the

operator should conduct a monthly walk-through inspection... or is this a DO walk thorough?- the monthly DO should conduct a walk-through inspection... 3 / 4

4

Facility lighting

Cathodic protection systems must be tested within ____months of installation and every ____months thereafter.tested within 6 months of installation and every 36 months thereafter.

Impressed current catholic protection systems shall be inspected no less then every___?30 days

The EPA suggested list of supplies for spill containment and

clean up include all the following EXCEPT:

Wet dry shop vacuum

  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 23, 2025
Description:

ICC California UST (Underground Storage Tank) Service Technician Exam includes accurate and verified questions covering California-specific UST regulations, system components, installation and main...

Get this document $30.00