What is the configuration when a fire dept switches from a duplex channel to a simplex channel for on-scene communications called?
- a talk around channel
- a repeater system
- an On scene communication switch
- a trunking system - ANSWER-a. a talk around channel
A trunked digital radio system allows?
- only one agency on the system
- different agencies on different systems
- different agencies on the same system 1 / 4
- | P a g e
- less users to communicate - ANSWER-c. different agencies
on the same system
Radio signals are either ?
- simple or duplex
- analog or digital
- simple or complex
- private or public - ANSWER-b. analog or digital
When operating on a digital radio system, end users should expect?
- a minor time delay between transmitting and receiving
- overlapping transmissions bleeding into one another
- an increase in the amount of static or interference
- the need for vehicle-mounted repeaters - ANSWER-a. a minor
time delay between transmitting and receiving
________ is the transition between the growth and fully developed stages of fire. 2 / 4
- | P a g e
- ignition temperature
- flash point
- backdraft
- flashover - ANSWER-d. flashover
Thermal layering is ?
- a column of heat rising from a source
- a process in which the molecules of a liquid are liberated into
- the configuration of heat with higher temperatures at the
- decomposition or transformation of a compound caused by
the atmosphere at a rate at which the molecules return to a liquid
upper levels and cooler temperatures at the lower levels
heat. - ANSWER-c. the configuration of heat with higher temperatures at the upper levels and cooler temperatures at the lower levels
When establishing a collapse zone around a building, the minimum distance from the building must extend
- the height of the building 3 / 4
- | P a g e
- dependent on the buildin'g construction type
- 1-1/2 times the height of the building
- whatever the safety officer decides is safe - ANSWER-c. 1-
1/2 times the height of the building
the least desirable point to force entry into a structure is
- a check rail window
- a swinging door
- plate glass
- a revolving door - ANSWER-d. a revolving door
Fire doors are operated
- manually, mechanically, electrically
- electrically, hydraulically, battery supplied
- by portable or fixed power units
- by manual or electrical power - ANSWER-a. manually,
mechanically, electrically
Slab doors are constructed in two configurations