SAE 609 EXAM QUESTIONS WITH
CORRECT ANSWER S
Question :The recovery process on an R-12 or R-134a
A/C System should continue until a stable vacuum is held
by the system for:
Correct answer:2 minutes
Question :A recycled refrigerant container has been
checked and found to be above the given pressure limit for the ambient temperatureTechnician A says that the refrigerant container should be placed in a cooler storage area before useTechnician B says that the vapor in the container should be slowly vented into a refrigerant handling unitwho's right
Correct answer:Technician B only
Question :The ozone layer filters out most of the suns
harmful:
Correct answer:Ultraviolet radiation
- | Page
Question :the reduction of ozone in the stratosphere could
cause:
Correct answer:An increase of skin cancer and eye
cataracts
Question :Technician A says that sunlight striking CFC
molecules can cause chlorine to be released Technician B says that chlorine atoms react with ozone to produce chlorine monoxideWho's right
Correct answer:Both A and B
Question :R 134a refrigerant must be reclaimed to meet
which of these purity standards
Correct answer:J2099
Question :if the required charge level of refrigerant for
MVAC system is 40 ounces which of these is correct charge level measured in pounds
Correct answer:2.50lb (1.13)
- | Page
Question :Technician A says that recovery/ recycling/
recharging equipment for R-1234yf refrigerant requires integration with a refrigerant identifier. Technician B says that recovery/ recycling/ recharging equipment for R- 1234yf refrigerant uses a 17.0 mm O.D. quick coupler on the low-side service hose.who's right
Correct answer:Technician A only
Question :Which of these identifies a cylinder of R-
1234yf refrigerant
Correct answer:White With red Band
Question :Which identifies R-12 refrigerant
Correct answer:White
Question :Which identifies R-134a
Correct answer:Light blue
Question :Which identifies R-744
- | Page
Correct answer:Gray
Question :A container of recycled R-134a refrigerant that
is being tested for non-condensable gases (air) should be:
Correct answer:Stored out of direct sunlight
Question :The EPA allows the use of R-134a recovery-
one equipment provided that the:
Correct answer:Equipment meets J2810 standards
Question :Technician A says that it is OKAY to use
disposable refrigerant tank to store recycled refrigerant Technician B says that it is OKAY to fill an approved refrigerant tank to 70% of it gross weight ratingwho's right
Correct answer:Neither A or B. Never store in disposable
container or fill above 60% of gross weight rating