A spring loaded self-closing valve could be part of an oil sampling manifold if? (pg. 3-4)

  • A spiral tube is downstream of the ball valve
  • The fittings upstream of the valve can handle the torque applied to
  • hold the valve open

  • The MP calls for it
  • The ball section is vented - ANSWER-B) The fittings upstream of the
  • valve can handle the torque applied to hold the valve open

Which statement is NOT true about lowering the discharge pressure on a condenser by running the evaporative condenser at full load? (pg. 4-6)

  • You can lower the head pressure so low that it will cause other
  • system problems

  • Lowering the head pressure while keeping the suction pressure
  • constant will reduce the amount of horsepower required by the compressor saving energy 1 / 4

  • | P a g e
  • Lowering the head pressure will save wear and tear on the
  • compressor

  • Lowering the head pressure will always make the system more
  • efficient and cost less to run - ANSWER-D) Lowering the head pressure will always make the system more efficient and cost less to run

Which of these statements are true about passivation in an evaporative condenser? (pg. 4-18)

  • During passivation you should keep the pH as low as possible,
  • preferably between 1 and 2

  • You should keep the pH between 7 and 8 during passivation
  • You are only concerned about passivating the tubes in an evaporator
  • condenser

  • After a condenser has been properly passivated, you never have to
  • worry about white rust again - ANSWER-B) You should keep the pH between 7 and 8 during passivation

Which is NOT a cause of scale formation on the evaporative condenser tubes? (pg. 4-18)

  • Improper water treatment
  • Plugged spray or partially plugged spray nozzles
  • Improper passivation of a new condenser
  • Not enough bleed water going down the drain - ANSWER-C)
  • Improper passivation of a new condenser

  • / 4
  • | P a g e

The purpose of the eliminators in an evaporative condenser is? (pg. 4- 21)

  • To eliminate the formation of scale on the tubes of the condenser
  • To prevent or eliminate the possibility of the water pumps cavitating
  • due to air entrainment

  • To prevent the formation of white rust
  • To prevent water droplets from being blown from the condenser -
  • ANSWER-D) To prevent water droplets from being blown from the condenser

The primary functional difference between a cooling tower and an evaporative condenser is where the? (pg. 4-7)

  • Refrigerant condenses
  • Where the unit must be shut down
  • Water distribution system is located
  • Filtration stream will be collected - ANSWER-A) Refrigerant
  • condenses

What are the two types of condenser designs for air flow? (pg. 4-23)

  • Forced draft and induced draft
  • Forced draft and up draft
  • Up draft and down draft
  • Centrifugal and axial - ANSWER-A) Forced draft and induced draft
  • / 4
  • | P a g e

Compressor efficiency increases when condensers? (pg. 4-6)

  • Use water on days with very high wet bulb
  • Lower discharge pressure
  • Are bottled up with liquid
  • Let the discharge pressure rise - ANSWER-B) Lower discharge
  • pressure

One of the most common causes of poor condenser performance is? (pg.

4-19,21)

  • Loose belt on the fans
  • Too much fans horsepower used
  • Scale on the condenser tube bundle
  • Too much water in the sump - ANSWER-C) Scale on the condenser
  • tube bundle

If you are having problems with the capacity of your condenser, you should check? (pg. 4-22)

  • Wet bulb temperature of the inlet air compared to the surrounding
  • area

  • The fit of the eliminators
  • Motor horsepower
  • For white rust buildup in the condenser - ANSWER-A) Wet bulb
  • temperature of the inlet air compared to the surrounding area

  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 5, 2025
Description:

RETA Industrial Refrigeration Book 3 Exam Newest 2025 Complete 200 Questions And Correct Answers (Verified Answers) |Already Graded A+ A spring loaded self-closing valve could be part of an oil sam...

Get this document $30.00