RAD 105 EXAM NEWEST 2025 ACTUAL EXAM

COMPLETE 300 QUESTIONS AND CORRECT

DETAILED ANSWERS (VERIFIED ANSWERS)

|ALREADY GRADED A+||BRAND NEW

VERSION!!

Question 1: What "across-the-board" adjustment in radiographic

techniques is recommended to allow for CR operation at the 400-speed class, reduce patient exposure, and avoid image mottle?

  • double all mAs values
  • cut all mAs values in half
  • increase all kVp levels by 15 per cent
  • reduce all kVp levels by 15 per cent

Correct answer: increase all kVp levels by 15 per cent

Question 2: If a department chooses to operate their CR or DR

system at the 200-speed class, what general adjustment in techniques must be made in changing from 400-speed rare earth

screens:

  • an overall doubling
  • a four-fold increase overall
  • | Page
  • a reduction to one-half
  • no change is required

Correct answer: an overall doubling

Question 3: For all digital imaging systems, a lower limit for

exposure to the receptor is imposed by:

  • the appearance of mottle
  • images turning out too light
  • the appearance of image fog
  • images turning out with excessive contrast

Correct answer: the appearance of mottle

Question 4: Which of the following are essential considerations

when using automatic exposure control with a DR or CR system?

  • the use of high kVp techniques
  • exact centering of the anatomy
  • correct selection of activated detectors
  • all of the above
  • | Page

Correct answer: all of the above

Question 5: mottle in a CR or DR image can result from:

  • insufficient kVp
  • insufficient mAs
  • improperly calibrated AEC
  • all of the above
  • b and c only

Correct answer: all of the above

Question 6: Which of the following artifacts is related to the

Nyquist frequency?

  • grid lines
  • aliasing artifact
  • heat blur
  • mottle

Correct answer: aliasing artifact

  • | Page

Question 7: For digital imaging, if a grid is not used:

  • the fog caused by scatter radiation will be transmitted through
  • to the final image

  • the final digital image will always turn out dark
  • the final digital image will always turn out light
  • the reduced signal-to-noise ratio from poor input data can
  • contribute to digital processing errors

Correct answer: the final digital image will always turn out dark

Question 8: Just as in conventional radiography, it is essential in

digital radiography that the original must have a high signal-to-

noise ratio:

  • laser beam
  • light emission from the phosphor plate
  • primary x-ray beam
  • remnant x-ray beam

Correct answer: remnant x-ray beam

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 2, 2025
Description:

RAD 105 EXAM NEWEST 2025 ACTUAL EXAM COMPLETE 300 QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+||BRAND NEW VERSION!! Question 1: What "across-the-board" adjustment in...

Get this document $30.00