RTTT 214-Dosimetry II Last Semester Questions with Complete Solutions (Latest 2025) A patient is treated at a distance of 70 cm SSD with a SDD of 49.8 cm. The source size is 1.5 cm. What is the geometric penumbra at a depth of 7.5 cm?

  • 0.65 cm
  • 0.83 cm
  • 1.20 cm
  • 3.26 cm
  • 3.83 cm - Correct Answers ✅0.83 cm
  • A patient is to be treated with 6 MV photons to a sarcoma of the leg, requiring an extended SSD of 130 cm. Compared with the PDD at 100 cm SSD, the PDD at 8 cm depth at 130 cm SSD will be approximately ______ than that at 100 cm SSD.

  • 0.5% greater
  • 3% greater
  • 10% greater
  • 5% less
  • 1.5% less - Correct Answers ✅3% greater
  • Which of the following represents the ratio of the dose at a given point in a phantom to the dose in free space at the same point? 1 / 4

RTTT 214-Dosimetry II Last Semester Questions with Complete Solutions (Latest 2025)

  • Scatter-air ratio (SAR)
  • Off-axis ratio
  • Tissue-phantom ratio (TPR)
  • Tissue-air ratio (TAR)
  • Tissue-maximum ratio (TMR) - Correct Answers ✅Tissue-
  • air ratio (TAR)

The side of the equivalent square of a 5 x 25 cm field is:

  • Approximately equal to the square root of (5x25)
  • Closer to 25 than 5
  • The square field, which has the same PDD as the rectangle
  • Approximated by the (area/perimeter of the rectangle) -
  • Correct Answers ✅The square field, which has the same PDD as the rectangle A patient was simulated for treatment on a linear accelerator at 100 cm SAD for a 10 cm x 10 cm field but has been scheduled for treatment on a Cobalt-60 at 80 cm SAD. If blocks need to be cut for the Cobalt-60 unit from the 100 cm film that has a target-to-film (TFD/SFD) distance of 150 cm, what TFD should be used? (Assume that the field size does not need to be adjusted) 2 / 4

RTTT 214-Dosimetry II Last Semester Questions with Complete Solutions (Latest 2025)

  • 120 cm
  • 130 cm
  • 150 cm
  • 188 cm
  • Cannot use the same simulator field, must re-simulate -
  • Correct Answers ✅120 cm What determines the wedge angle?

  • The angle of the 100% isodose line with a line
  • perpendicular to the central axis

  • The actual measurements of the wedge
  • The angle of the 80% isodose line with a line perpendicular
  • to the central axis

  • 2 times the hinge angle - Correct Answers ✅The angle
  • of the 80% isodose line with a line perpendicular to the central axis

  • times the hinge angle

As the SSD increase, the PDD:

  • Increases 3 / 4

RTTT 214-Dosimetry II Last Semester Questions with Complete Solutions (Latest 2025)

  • Decreases
  • Remains the same
  • There is no effect - Correct Answers ✅Increases
  • Which of the following is a plot of target or normal structure volume as a function of dose?

  • BEV
  • DVH
  • DRR
  • REV - Correct Answers ✅DVH

As the field size increases, the PDD:

  • Increase
  • Decrease
  • Remains the same
  • There is no effect - Correct Answers ✅Increase
  • Which of the following accounts for target motion and uncertainty in positioning?

  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 1, 2025
Description:

RTTT 214-Dosimetry II Last Semester Questions with Complete Solutions (Latest 2025) A patient is treated at a distance of 70 cm SSD with a SDD of 49.8 cm. The source size is 1.5 cm. What is the geo...

Get this document $30.00