QSP EXAM 2023-2024 LATEST EXAM 150 QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED ANSWERS )
|ALREADY GRADED A
Stockpiles require a linear sediment barrier at all times, and must be covered prior to a rain event or when inactive. A stockpile is inactive after __days of inactivity.
- 3
- 7
- 10
- 14 - ANSWER- D
Once identified, dischargers shall begin implementing repairs or design changes to
BMPs:
- Immediately
- Within24 hours
- Within48 hours
- ASAP, but not more than 72 hours - ANSWER- D
The discharger shall ensure a QSP develop a Rain Event Action Plan (REAP) __ hours prior to any likely precipitation event.
- Immediately
- 24 hours
- 48 hours
- ASAP but not more than 72 hours - ANSWER- C
A likely precipitation event is any weather pattern that is forecasted to have a __% or greater probability of producing precipitation in the project area.
- 10
- 25
- 50
- 75
- 99 - ANSWER- C
TRUE OR FALSE: At Risk Level 2 & 3 sites, receiving water monitoring is
required if the receiving water monitoring trigger exceeded pH, turbidity and SSC.Bioassessment for sites 30 acres or larger. - ANSWER- False (Risk level 3 only)
- / 2
Visual monitoring is required for non-storm water, pre-rain and post-rain at what Risk Levels?
- Risk Level 1
- Risk Level 2
- Risk Level 3
- All of the above
- Risk Level 1 & 2 - ANSWER- D
A storm that produces ½ inch or more of precipitation, with a 48 hour or greater period between rain events is a/an...
- Qualifying rain event
- Extended storm event
- Inactive storm event
- Unsafe monitoring event - ANSWER- A
Upload photos to SMARTS that are taken during daily inspections of the LUP site before, during, and after every ___ storm event
- First
- Second
- Third
- Fourth - ANSWER- C
Which statement is false? Monitoring is not required when:
- the site/sampling locations are unsafe to access due to the storm event
- it is outside of scheduled site operation hours
- the contractor elects not to work and the site is "shut down" for a rainy day -
ANSWER- C
What is the Numeric Action Level (NAL) for pH?
- 3.5-5.5
- 6.0-9.0
- 6.5-8.5
- 9.0-12.0 - ANSWER- C
What is the exceedance trigger for Receiving Water Monitoring?
- 100 NTU
- 250 NTU
- 500 NTU
- 1,000 NTU - ANSWER- C
- / 2