Nyc high pressure boiler license Exam Latest

Study Guides Aug 17, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

Nyc high pressure boiler license Exam Latest Update 380 Questions and Correct Answers Guaranteed Success ________ is the term used with a wet absorber nozzle in relation to an incinerator? - Correct Answer: : slurry

(TS x t x E) / (R x FS)

TS = - Correct Answer: : tensile strength of shell plates

(TS x t x E) / (R x FS) E = - Correct Answer: : efficiency of longitudinal joint

(TS x t x E) / (R x FS) FS = - Correct Answer: : factor of safety allowed by this subpart

(TS x t x E) / (R x FS) R = - Correct Answer: : inside radius of weakest course of shell or drum

(TS x t x E) / (R x FS) t = - Correct Answer: : thickness of shell plate

  • pound of water increases by ____ Xs when turned into steam. - Correct Answer: :
  • the volume of steam is over 1600 times more than the volume of water

1cfm for every ___btu's in accordance with forced combustion air - Correct Answer: : 2400 btu's

5/16" tube thickness w/ no bevel or recess should extend how far past tube sheet? - Correct Answer: : 3/8", 5/16", 1/2" (code says at least same as pipe thickness)

800 psi safety valve, at what pressure does it lift? - Correct Answer: : 824 psi (3%)

a boiler operates at 100 psig, how many fusible plugs are there? - Correct Answer: : 1 fusible plug (over 50 sq ft)

a boiler operates at 300 psi, it is tested once ___? - Correct Answer: : once a month and pressure tested annually

a boiler operating at 100 psi mawp, how are pipes joined together? - Correct Answer: : flanged or welded

a combustion regulator prevents water from rising above ___*F or a steam pressure of ___ in relation to LPB. - Correct Answer: : 250*F or a steam pressure of 15 psig 1 / 3

a fuel regulating governor is controlled by? - Correct Answer: : steam pressure

A heater for either liquid fuels or other liquids harmful to the boiler shall not be installed? - Correct Answer: : Directly in the steam or water space within the boiler

a low pressure boiler needs inspection if it occupies more than ___ families? - Correct Answer: : 6

a LP hot water boiler is considered low pressure below? - Correct Answer: : 160 psig

@ 250*F

a miniature boiler has less than ____ MAWP. - Correct Answer: : less than 100 MAWP (PSI)

a miniature boiler has up to __ cubic feet of gross volume. - Correct Answer: : 5 cubic feet of gross volume

a miniature boiler has up to __ sq ft of heating surface. - Correct Answer: : 20 sq ft of heating surface

a miniature boiler has up to __" of ID of shell? - Correct Answer: : 16" inner diameter

A non return type steam trap discharges directly to the? - Correct Answer: : Receiver or heater

a safety valve over 3" and over 15 psig shall have what type of inlet connection? - Correct Answer: : flanged or welded

After an inspectors notice is given to the owner where is it posted? - Correct Answer: : On or close to the boiler

After an inspectors notice is given to the owner where is it posted? - Correct Answer: : On or close to the boiler

After welded repairs or alterations of the equipment, what shall retain a copy of the report? - Correct Answer: : The owner

all boiler fittings are what standard? - Correct Answer: : ASME

all miniature boiler openings in the boiler shall be (construction) _____ or _____ reinforcement? how many threads? - Correct Answer: : mechanical construction with a minimum 4 threads or welded

all piping over 2" shall be ___ welded or ___? - Correct Answer: : socket welded or flanged 2 / 3

all piping over 2" shall be ___ welded? - Correct Answer: : butt welded

Any boiler changing location within the state may be reinstalled; an application for permission to install a second boiler is filled with whom? - Correct Answer: : Commissioner

any mouth protector on a boiler shall be locked or sealed ____, what type? - Correct Answer: : locked or sealed open, of the straight way type

any valve used as a shut off to a water column shall be sealed ____ and ____. - Correct Answer: : sealed open and locked

At what percent do you hydrostatically test a boiler? - Correct Answer: : 150%

At what percent do you hydrostatically test a boiler? - Correct Answer: : 150%

at what pressure is a fusible plug NOT needed? - Correct Answer: : under 200 psi

At what pressure is it requires to have extra heavy valves installed? - Correct Answer: : 100 psig

bad water treatment and scaling would most effect? - Correct Answer: : shutdown and startup, cycling and base load

Before the clean air act, concerned with? - Correct Answer: : Particulate matter, sulfur dioxide, CO2

benefit of globe valve - Correct Answer: : valves are not cut by throttling and valve parts are easy to repair and replace

Beside a log book being inspected by a state boiler inspector who else can look at the book? - Correct Answer: : the insurance company

Beside a log book being inspected by a state boiler inspector who else can look at the book? - Correct Answer: : the insurance company

boilers have 2 bottom blow downs when the MAWP exceeds _____ psi. - Correct Answer: : 100 psi

Boilers shall have all controls set, adjusted and tested by - Correct Answer: : The installer

brass pipes cannot be joined by - Correct Answer: : solder

  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 17, 2025
Description:

Nyc high pressure boiler license Exam Latest Update 380 Questions and Correct Answers Guaranteed Success ________ is the term used with a wet absorber nozzle in relation to an incinerator? - Correc...

Get this document $30.00