Nocti Hvac study guide Questions and Correct Answers

(a) Question :When one rises into the atmosphere, the

atmospheric pressure decreases by 1 psi for every

  • 2,343 feet
  • 3,343 feet
  • 2,500 feet
  • 5,280 feet

Correct answer:2,343 feet

Question :geothermal heat pump

Correct answer:An HVAC system that depends on the

temperatures below the ground surface as an operation factor is a

Question :Class B

Correct answer:When putting out a fire involving oily rags

use a _______ fire extinguisher

Question :refrigeration service

Correct answer:the best tool to open and close the stem access

valve on a refrigertion system is the _____ wrench

  • | P a g e

Question :sawzall

Correct answer:Which power tool is best used for cutting steel

rod?

Question :floor plan

Correct answer:When reading blueprints for a proper wall and

duct location, the technician should look at

Question :can be used with both natural gas and propane

equipment

Correct answer:CSST (Corrugated Stainless Steel Tubing)

connections

Question :PVC

Correct answer:The type of pipe commonly used for

condensation drainage on central air conditioning system is

Question :always be on the regulator

Correct answer:When pressure testing a completed copper

tubing assembly with pressurized nitrogen, the nitrogen cylinder should

  • | P a g e

Question :glue specified for PVC pipe

Correct answer:Connections should be permanently

connected with _____ on drainage piping asemblies that use PVC piping

Question :could cause an explosion

Correct answer:using oxygen to purge copper tubing after

brazing

Question :Two gases that considered non-condensable in a

refrigeration

Correct answer:Air and Nitrogen

Question :Residential air condition system have a super heat

range of ____ degress under normal operating conditions?

Correct answer:8 to 12

Question :which is not a condition of low superheat on an air

conditioning system

Correct answer:Refrigerant undercharged

Question :The reason that subcooling would be below 8

degrees on air conditiong system

  • | P a g e

Correct answer:dirty or blocked condenser coil

Question :The cause for exessive subcoolinf in an air

conditoning system ?

Correct answer:system operating in low abient conditions

Question :when reading blue prints for proper wall and duct

location, the technician should look at the ______

Correct answer:Floor plan

Question :When trouble shooting an air conditioning system,

the operating pressures mare 40 psig on the low side and 116 in the high side, what would be the most likely problem?

Correct answer:Refrigerant Leak

Question :When trouble shooting an air conditioning system

and you notice frost on the suction line, what would be the problem?

Correct answer:Dirty air filter

Question :An Hvac system that depends on the temperatures

below the ground surface as an operation factor is a/an______?

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 16, 2025
Description:

Nocti Hvac study guide Questions and Correct Answers (a) Question :When one rises into the atmosphere, the atmospheric pressure decreases by 1 psi for every A. 2,343 feet B. 3,343 feet C. 2,500 fee...

Get this document $30.00