NICET LEVEL 2 NEWEST 2025 ACTUAL EXAM

Construction and Industry Aug 3, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

  • | P a g e

NICET LEVEL 2 NEWEST 2025 ACTUAL EXAM

COMPLETE 100 QUESTIONS AND CORRECT

DETAILED ANSWERS (VERIFIED ANSWERS)

|ALREADY GRADED A+ (BRAND NEW VERSION!)

Where replacing residential sprinklers manufactured prior to 2003 that are no longer available from the manufacturer and are installed using a design density less than 0.05 gpm/ft2, a residential sprinkler with an equivalent K-factor (+/- ______ percent) shall be permitted to be used provided the currently listed coverage area for the replacement sprinkler is not exceeded.5

CONSIDER A STANDPIPE AND HOSE SYSTEM WITH A

HYDRAULIC DESIGN INFORMATION SIGN. WHEN

INSPECTING THE INFORMATION SIGN, WHERE

SHOULD IT BE LOCATED FOR AUTOMATIC AND SEMI

AUTOMATIC SYSTEMS?

Secured to the water supply control valves

  • / 4
  • | P a g e

Dry barrel and wall hydrants shall be inspected ______ and after each operation?Annually

Which of the following would be considered noncritical deficiency? (Select 3)

  • A hose rack that only swings out of the cabinet 120 degrees
  • A hose/hydrant house not fully equipped
  • A hose on standpipe that is not connected
  • A hose connection on a pressure reducing valve with a
  • missing cap

  • A hose/hydrant house not fully equipped
  • A hose on standpipe that is not connected
  • A hose connection on a pressure reducing valve with a
  • missing cap

When inspecting a diesel fire pump, the fuel tank shall be at least ______ full?Two thirds 2 / 4

  • | P a g e

Consider a water storage tank with a low temperature alarm connected to a constantly attended location. What is the inspection frequency for the water temperature?Quarterly

What is the visual inspection frequency of a room temperature supervisory signaling switch?Quarterly

All pressure gauges used for hydrant testing should be calibrated at least every _______ or more frequently depending on use Year

While conducting a full flow trip test of a dry pipe system, the tester at the inspector's test valve notes the time when water flows steadily from the test connection. This time is noted for 3 / 4

  • | P a g e

comparison purposes for previous tests. Which of the following is true regarding water delivery?NFPA 13 does not require water delivery in 60 seconds for all systems

Each portable wooden ladder shall support at least _____ times the maximum intended load?4

A section of piping on a standpipe system has been replaced. As a result, the system shall be hydrostatically tested in conformance with NFPA ____?14

When measuring the pitot pressure of a stream of practically uniform velocity, the orifice in the pitot tube is held down stream approximately _____ the diameter of the hydrant outlet or nozzle opening and in the center of the stream one-half

  • / 4

Download Document

Buy This Document