Magnetic Resonance Safety Expert (MRSE) –Exam Questions and Answers | Updated Certification

Question : Formula for temperature change in a patient

CORRECT ANSWER : dTp/dt = SAR/C, where C = 4186

J/kg, Tp = temperature

Question : How much does liquid helium expand when

transitioning to gaseous helium?

CORRECT ANSWER : >700x

Question : Electric field density (JE) formula

CORRECT ANSWER: JE = Conductivity x electric field

strength x B0 x V where V = velocity?

Question : What is the most accurate way to measure energy

dose to the patient?

CORRECT ANSWER : B1 + rms

Question : Kinetic stability

CORRECT ANSWER : The rate at which a gadolinium

agent dissociates

Question : Thermodynamic stability

CORRECT ANSWER : the change that a gadolinium agent

will transmetallate

Question : Diamagnetic

CORRECT ANSWER : Very small negative magnetic

susceptibility (X), two electrons in an orbital

Question : Paramagnetic

CORRECT ANSWER : Very small positive magnetic

susceptibility (X), one electron in an orbital

Question : Ferromagnetic

CORRECT ANSWER : very large positive magnetic

susceptibility (X), domains of directional magnetism that can

align with an external field, retains magnetism after being removed from field

Question : RF Pulse power (heating) formula

CORRECT ANSWER : Power = Flip Angle ^2 x (Tp / Tr)

where Tp = pulse duration, Tr =

Question : Slew rate formula

CORRECT ANSWER : Maximum Gradient Strength

(mT/m) / Rise Time (ms)

Question : What parameters can be changed to reduce

Peripheral Nerve Stimulation (PNS)?

CORRECT ANSWER : Increase rise time (reduces slew

rate), decrease matrix/phase encoding (reduces slope of gradient), increasing slice thickness (shallower slice selection gradient), increase FOV (shallower frequency encoding gradient), phase noise-canceling (opposite frequency to noise), increase echo time TE

Question : Nitinol is (paramagnetic/diamagnet/ferromagnetic)

CORRECT ANSW ER: paramagnetic

Question : What quantitative property of the gradient coils is

responsible for Peripheral Nerve Stimulation (PNS)?

CORRECT ANSWER : slew rate

Question : What contrast agents are the most stable?

CORRECT ANSWER : macrocyclic, ionic

Question : What is a common dose of gadolinium?

CORRECT ANSWER : 0.1 mmol/kg

Question : In what direction relative to the magnetic flux will

the strongest Lenz's force be produced?

CORRECT ANSWER : antiparallel

Question : What is the ASTM duration of time defined for

heating effects?

CORRECT ANSWER : 15 mins continuous scanning

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 18, 2025
Description:

Magnetic Resonance Safety Expert (MRSE) –Exam Questions and Answers | Updated Certification Question : Formula for temperature change in a patient CORRECT ANSWER : dTp/dt = SAR/C, where C = 4186 ...

Get this document $30.00