Mosby's CT Simulated Exam Questions and Verified Answers, 100% Guarantee Pass (Latest 2025)
- As related to the cardiac cycle, the term ______ refers to
- diastole
- equilibrium
- systole
- a-fib - Correct Answers ✅a. diastole
- Which of the following may be considered one of the high-
- iothalamate meglumine
- diatrizoate sodium
- iohexol
- 1 only
- 3 only
- 1 and 2
- 1, 2, and 3 - Correct Answers ✅c. 1 and 2
- Which of the following technical changes would serve to
- increase in matrix size
- change from soft tissue to bone algorithm
- decrease of tube rotation from 360 to 180 degrees 1 / 4
the relaxation of heart muscle.
osmolar contrast media (HOCM)?
decrease patient radiation dose during a CT examination?
Mosby's CT Simulated Exam Questions and Verified Answers, 100% Guarantee Pass (Latest 2025)
- decrease in DFOV - Correct Answers ✅c. decrease of
- Which of the following medications may be administered to
- epinephrine
- atropine
- diphenhydramine
- 1 only
- 1 and 2
- 1 and 3
- 1, 2, and 3 - Correct Answers ✅c. 1 and 3
tube rotation from 360 to 180 degrees (Many CT scanners allow the tech to reduce the total rotation of the x-ray tube, thus reducing the scan time and subsequent patient radiation dose. This type of partial scan, commonly referred to as "half-scan" or segmenting, is most often used to improve the temporal resolution of the acquisition)
a patient who is having a severe anaphylactoid reaction to iodinated contrast material?
(Epinephrine [Adrenalin] is an adrenergic drug used as a bronchodilator. Diphenydramine [Benadryl] may be used to block the physiologic effects of the body's release of 2 / 4
Mosby's CT Simulated Exam Questions and Verified Answers, 100% Guarantee Pass (Latest 2025) histamine, thus reducing the allergic effect of the contrast material. Atropine should be used only to combat bradycardia during a vagal reaction to contrast media)
- In an effort to reduce patient radiation dose, the technical
factors of the applied CT protocol should be optimized on the
basis of:
- age
- sex
- size or weight
- physical condition - Correct Answers ✅c. size or weight
- The escape of contrast material from a needle or blood
vessel into the subcutaneous tissues is called:
- infusion
- extraversion
- influxation
- extravasation - Correct Answers ✅d. extravasation
- Thorough explanation of the CT procedure and proper
communication with the patient are vital in ensuring that:
- breathing instructions are properly followed
- motion artifact does not occur 3 / 4
Mosby's CT Simulated Exam Questions and Verified Answers, 100% Guarantee Pass (Latest 2025)
- patient anxiety is kept at a minimum
- 1 and 2
- 1 and 3
- 2 and 3
- 1, 2, and 3 - Correct Answers ✅d. 1, 2, and 3
- Which of the following is considered in the calculation of
- bed index
- gantry rotation time
- mA setting
- pitch - Correct Answers ✅a. bed index
- Risk factors for contrast-induced nephrotoxicity (CIN)
the MSAD for an axial (step-and-shoot) CT exam?
(MSAD [multiple scan average dose] accounts for the effects of image spacing, or bed index, on patient radiation dose during axial scanning. *MSAD increases when slice thickness is greater than image spacing* and decreases when slice thickness is less than the bed index)
include:
- pheochromocytoma
- / 4