LOAD CALCULATION FEE DERS AND

SERVICES LEVEL 4 MOD ULE 1 |

QUESTIONS WITH 100% CORRECT

ANSWERS | VERIFIED | LATEST

UPDATE

Question :What is the demand factor allowed by the NEC®

for calculating the neutral conductor size for electric range load?

Correct answer:70%

Question :Using the VA/linear foot method, the total VA that

must be used in a service calculation for a 50' show window is

Correct answer:12,500VA

Question :Before it is considered a continuous load, a load

must operate for at least how many hours without interruption?

Correct answer:3

  • | Page

Question :Which of the following factors does not affect

conductor ampacity adjustments?

Correct answer:Number of phase

Question :If a continuous connected load totals 120A, what is

the minimum current-carrying capacity required for the feeder?

Correct answer:150A

Question :What is the load center length for a tapped feeder

with loads of 120A at 50', 110A at 60', 75A at 90', and 70A at 150'?

Correct answer:79.60

Question :Which of the following lighting loads would be

used in a residence that is 1,650 sq ft?

Correct answer:4,950VA

Question :What is the load for 40 non-dwelling unit

receptacles? (Assume that the load is not continuous.)

  • | Page

Correct answer:7,200VA

Question :The minimum service rating for a residential

service is

Correct answer:100A

Question :Residential small appliance circuit must be rated at

Correct answer:1,500VA

Question :Use of the 100' tap rule is limited to installation in

high-bay manufacturing buildings with wall heignt over

Correct answer:35 feet

Question :Which part of a residential lighting and small

appliance load must be rated at 35% for service calculations?

Correct answer:The next 177,000VA

Question :If a store lighting load is 14,000VA (continuous),

which of the following must be used for the circuit calculation?

  • | Page

Correct answer:17,500VA

Question :In most cases, feeder conductor size is adjusted

when

Correct answer:there are more than three current-carrying

conductors in the raceway

Question :When calculating the service requirement for a

particular building, the step is to

Correct answer:determine the floor area of the building

Question :What is the feeder ampacity for a three-phase,

120/208V subpanel with a connected load of 84,563VA?

Correct answer:235A

Question :An optional method for determining feeder to

schools is covered in

Correct answer:NEC® Section 220.86

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 18, 2025
Description:

LOAD CALCULATION FEE DERS AND SERVICES LEVEL 4 MOD ULE 1 | QUESTIONS WITH 100% CORRECT ANSWERS | VERIFIED | LATEST UPDATE Question :What is the demand factor allowed by the NEC® for calculating th...

Get this document $30.00