LMRT State Review EXAM QUESTIONS

Study Guides Aug 1, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

LMRT State Review EXAM QUESTIONS AND ANSWERS 100% SOLVED (Newest 2025) Which of the following statements are correct regarding the link between radiation dose and genetic effects?

  • The link has been demonstrated in human studies.
  • The link has been demonstrated in animal studies.
  • increased risk to humans cannot be predicted with respect
  • to an individual. - Correct Answers ✅2 and 3 only Which of the following changes in kilovoltage (KVP) will result in the greatest reduction of patient dose, when milliamperage-seconds (mAs) is adjusted to compensate for the dosage?A.) Decrease kVp by 30% B.) Decrease kVp by 15% C.) Increase kVp by 15% D.) Increase kVp by 30% - Correct Answers ✅Increase kVp by 30% Which of the following image receptor (IR) system speeds will result in the lowest patient dose?A.) slower speed IR system B.) Faster speed IR system C.) It does not matter; the IR system speed does not affect the patient dose. - Correct Answers ✅Faster speed IR system 1 / 4

LMRT State Review EXAM QUESTIONS AND ANSWERS 100% SOLVED (Newest 2025) What is the primary purpose of using gonad shields during radiography?A.) Reduce the likelihood of genetic changes B.) Reduce likelihood of somatic effects C.) Protect patient modesty D.) Demonstrate the location of the gonads in the image - Correct Answers ✅Reduce the likelihood of genetic changes Which one of the following are types of gonad shields?

  • Aperture
  • Contact
  • Shadow
  • A.) 1 and 2 only B.) 1 and 3 only C.) 2 and 3 only D.) 1, 2, and 3 - Correct Answers ✅2 and 3 only When should gonad shielding be used?A.) for all patients B.) For all procedures C.) when the gonads are within 10 cm of the radiation field 2 / 4

LMRT State Review EXAM QUESTIONS AND ANSWERS 100% SOLVED (Newest 2025) D.) when the gonads are within 5 cm of the radiation field - Correct Answers ✅when the gonads are within 5 cm of the radiation field The greatest cause of unnecessary radiation to patients that

can be controlled by the limited operator is:

A.) Patient condition B.) Patient size C.) Repeat exposure D.) equipment malfunction - Correct Answers ✅Repeat exposure

The limited operator can reduce repeat exposures by:

A.) Accepting marginal images B.) Clearly instructing patients C.) increasing the source-image receptor distance (SID) D.) optimizing the kVp - Correct Answers ✅Clearly instructing patients How does x-ray beam restriction minimize patient exposure?A.) it limits radiation fog B.) It limits the radiation field to the area of interest C.) It limits the effect of patient motion 3 / 4

LMRT State Review EXAM QUESTIONS AND ANSWERS 100% SOLVED (Newest 2025) D.) It limits repeat exposure - Correct Answers ✅It limits the radiation field to the area of interest What is the device that allows the limited operator to vary the size of the radiation field?A.) Collimator B.) Detent C.) Filter D.) Sheild - Correct Answers ✅Collimator How does filtration reduce patient exposure?A.) Removes the shorter-wavelength photons B.) Removes longer wavelength photons C.) Reduces the size of the radiation field D.) Reduces the time of exposure - Correct Answers ✅Removes longer wavelength photons What is the National Council on Radiation Protection and Measurements (NCRP) recommendation for the amount of total filtration?A.) 0.5mm aluminum equivalent ( AL Equiv) B.) 1.5mm AL Equiv C.) 2.5mm Al Equiv

  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 1, 2025
Description:

LMRT State Review EXAM QUESTIONS AND ANSWERS 100% SOLVED (Newest 2025) Which of the following statements are correct regarding the link between radiation dose and genetic effects? 1. The link has b...

Get this document $30.00