Latest Questions With Complete Grade A Answers

Study Guides Aug 17, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

2024 CNIM Section II Latest Questions With Complete Grade A Answers

  • An objective measure of meaningful change to use to warn the surgeon is the

Answer: 50% amplitude decrease.

  • D-Wave amplitude_ and latency as you move caudally down the spinal cord.

Answer: decreases, increases

  • Where is the BAEP wave V generated?

Answer: Midbrain

  • Electrocochleogram (EcochG)

Answer: All are correct

  • The absence of N20 obligate waveform may reflect a

Answer: Subcortical lesion of the ascending somatosensory pathway

  • What is the effect of nerve ischemia on EMG?

Answer: No detectible EMG activity

7. The stimulation rate most suitable for tibial SSEP monitoring is:

Answer: 2.1 Hz.

  • According to the ACNS guidelines, what is the most appropriate repetition rate for SSEP
  • stimulation?

Answer: 2-8/sec

9. Contralateral masking should be used during BAEP monitoring to:

Answer: Prevent crossover responses

  • Which cranial nerves are at greatest risk of injury during a retrosigmoid acoustic neuroma
  • surgical approach?

Answer: CN 7 and 8

  • According to ACNS Guidelines, which of the following will result in reduction of
  • stimulus artifact and rapid acquisition of data?

Answer: Alternating polarity and a stimulus rate of 30.1 p/sec.

  • When monitoring from external anal sphincter, where should electrodes be placed?

Answer: 2 finger breadths laterally from the edge of the rectum

  • / 2
  • If you have noise in ALL SSEP channels, replacing which electrode would be most
  • beneficial?

Answer: Ground electrode

  • A risk associated with mapping of the motor cortex is

Answer: Seizures

  • During pre-operative posterior tibial nerve somatosensory evoked potentials, which of the
  • following would be the best ipsilateral location for the ground electrode?

Answer: Calf

  • To display median nerve SSEP response as an upward deflection, which of the following
  • must be known?

Answer: Waveform polarity and polarity convention of the amplifier inputs

  • During carotid endarterectomy, Spectral Edge Frequency is usually set to

Answer: 90%-97%

  • Which of the following anesthetic agents may increase the amplitude of cortical
  • potentials?

Answer: Etomidate

  • Cervicomedullary signal

Answer: P31

20. In a full-field pattern reversal VEP, the maximal response is seen at:

Answer: MO

  • Due to immature myelination and smaller neural fibers, children may re- quire to obtain
  • TCEMEP responses.

Answer: A higher stimulation intensity

  • An EEG frequency of 4-7 Hz

Answer: Theta

  • Which of the following is the largest bio-potential source of artifact for the BAEP?

Answer: Electromyogram

  • Which enzyme abnormality can cause TOF to show 0/4 twitches when no neuro muscular
  • blockade has been given since induction?

Answer: Pseudo- cholinesterase deficiency

  • / 2

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 17, 2025
Description:

2024 CNIM Section II Latest Questions With Complete Grade A Answers 1. An objective measure of meaningful change to use to warn the surgeon is the Answer: 50% amplitude decrease. 2. D-Wave amplitud...

Get this document $30.00