LATEST IICRC WRT EXAM 2024 WITH

Study Guides Aug 2, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

pg. 1

LATEST IICRC WRT EXAM 2024 WITH

300 PREP QUESTIONS AND CORRECT

ANSWERS/ IICRC WRT TEST PRACTICE

QUESTIONS AND CORRECT ANSWERS

(BRAND NEW!)

  • During the inspection process, restorers shall make a reasonable effort to -
  • ANSWER-C. identify and address potential safety hazards

#2. A significant amount of water absorption and evaporation load where wet porous materials represent ~5% to ~40% of combined ceiling, walls, and flooring surface areas and where low evaporation materials and assemblies are minimally wet is - ANSWER-B. class 2

#3. Multiple extraction of salvageable materials, especially porous material (e.g.

Carpet , cushion) often are required to: - ANSWER-decrease drying time

#4. To enhance drying, restorers should manage both ambient temperature and - ANSWER-surface temperatures of affected materials

#5. Water damage restoration services should not begin until after the: -

ANSWER-restorer has entered into an adequately written contract.

#6. Two tools that should be used to properly disengage most stretched-in carpet - ANSWER-Knee kicker and carpet awl

  • / 4

pg. 2

#7. When inspecting a water damage structure, restorers should inspect: -

ANSWER-all potentially affected areas.

#8. Buckled or damaged particle board should - ANSWER-removed and replaced with new material.

#9. upon entering a building, professional moisture detection equipment should be

used to evaluate and document: - ANSWER-applicable psychrometric conditions

and moisture content or level readings .

#10. When wet, a structural material that loses most of its structural integrity, but

regains its strength when dry, is: - ANSWER-Concrete

#11 Initially, a method of search for abnormal moisture behind ceramic tile or resilient flooring can be accomplished by - ANSWER-using a non-penetrating (non-invasive) moisture meter

#12. To minimize damage and reduce drying time, reduce drying time, restorers

should: - ANSWER-begin mitigation as soon as safely possible

#13. The moisture content of structural materials should be measured with a - ANSWER-A. moisture meter

#14. When accessible from below, to dry wet wood subflooring under stone or tile flooring, restorers can use low-humidity air and - ANSWER-D. vapor barrier

#15. Biocides designed to destroy or eliminate all forms of microbial life and their spores are - ANSWER-D. sterilizers

  • / 4

pg. 3 #16. When carpet is wet it can be delaminated by - ANSWER-D. improper handling and disengaging

#17. To minimize or control aerosolized soils or contaminants during restoration,

restorers can: - ANSWER-B. install one or more air filtration devices (AFDs)

#18. When pre-existing damage is discovered, restorer should - ANSWER-D.document and bring it to the attention of materially interested parties

#19. Rapid drying of structural materials is achieved by - ANSWER-A. promoting evaporation and dehumidification or ventilation

#20. When carpet and cushion (pad, underlay) are saturated with Category 3 water

  • ANSWER-B. Both should be removed for proper disposal

#21. To minimize safety concerns and to speed structural drying, gypsum board (drywall) ceilings that are saturated and sagging should be - ANSWER-A. drained, removed quickly, and properly disposed

#22. The force exerted by water molecules in the air on surrounding surfaces is - ANSWER-b. Vapor Pressure (page 11)

#23. Generally, fastest rate of evaporation from wet materials with a 70F (21C) surface temperature [0.67 VP] would be an environment with - ANSWER-A. 60F (4C) and 80% RH

#24. Two hazardous materials more likely found in older building that require compliance with laws and regulations when handled are - ANSWER-C. lead-based paint and asbestos 3 / 4

pg. 4

#25. As humidity ratio increases (or decreases) another psychrometric chart property that also increases (or decreases) is - ANSWER-C. vapor pressure

#26. Ventilating a structure during the initial stages of restoration can be effective way to enhance drying by reducing the build up of - ANSWER-C. humidity

#27. When using government-registered biocide, restorers shall - ANSWER-C.apply according to label directions

#28. Intentionally using outdoor air to reduce indoor humidity is known as - ANSWER-B. an open drying system

#29. To confirm that proper drying conditions were established and also that

drying goals were met, restorers should maintain written logs to include: -

ANSWER-B. an atmospheric humidity record and materials moisture content record

#30. A closed drying system is recommended during restoration when - ANSWER-A. outdoor humidity ratio is higher than indoor humidity ratio

#31. the rating for water removal of refrigerant dehumidification normally is expressed in pints of water removed in 24 hours at standard AHAM test conditions of - ANSWER-C. 80 F (27C) and 60% RH

#32. The temperature at which air reaches 100% relative humidity is known as the

  • ANSWER-C. dew point temperature
  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 2, 2025
Description:

pg. 1 LATEST IICRC WRT EXAM 2024 WITH 300 PREP QUESTIONS AND CORRECT ANSWERS/ IICRC WRT TEST PRACTICE QUESTIONS AND CORRECT ANSWERS (BRAND NEW!) 1. During the inspection process, restorers shall ma...

Get this document $30.00