IICL Container Inspector's Exam Questions And Answers
Question 1: Which of the following defects requires repair?
- A loose door gasket
- A bent J-bar that does not affect door operation
- A dent 13mm (1/2 in) deep on the door sill
- Four dents, each 11mm (7/16 in) deep, on contiguous
outboard corrugations of a roof panel
CORRECT ANSWER : A. A loose door gasket
Question 2: Of the following conditions in a dry-van
container, which one would require cleaning?
- Raised mud foot prints in excess of what might normally
- Dry dust covering dried floor stains as might normally be
- Coffee beans remaining inside the container as might occur
remain after a sweep out
found after a sweep out
after a sweep out
- Polyurethane beads as might be expected to lodge in
grooves between floorboards after a sweep out
CORRECT ANSWER : C. Coffee beans remaining inside the
container as might occur after a sweep out
Question 3: An Equipment Interchange Receipt (EIR), based
on an inspection with no damage found, can be evidence of a
container's compliance with:
- Australian Timber Component Treatment Regulations
- Convention for Safe Containers (CSC) regulations through
- Transport under custom's seal (TIR) regulations
- International Standards Organization (ISO) CEDEX codes
the ACEP Program
regulations
CORRECT ANSWER : B. Convention for Safe Containers
(CSC) regulations through the ACEP Program
Question 4: The top of a replacement plastic ventilator should
be centered what distance from the top side rail?
- 50-55mm (2-2 3/16 in)
- 70-75mm (2 5/8 - 3 in)
- 100mm (4in)
- 150mm (6 in)
CORRECT ANSWER : A. 50-55mm (2-2 3/16 in)
Question 5: When must a reference line extend the full length
of a bottom side rail?
- When there are two or more areas of damage on the
- When there is a sharp bend in the bottom side rail
- When there is a bowing over the entire bottom side rail
- When there is additional damage to the bottom side rail so
bottom side rail
that the reference line cannot be positioned over the ends of the damage
CORRECT ANSWER : C. When there is a bowing over the
entire bottom side rail
Question 6: Which of the following is NOT a transverse
structural member of the container?
- Front sill
- Tunnel rail
- Rear header
- Crossmember
CORRECT ANSWER : B. Tunnel rail
Question 7: A steel corner fitting is being replaced. To ensure
better weld penetration, IICL recommends that the edges of parts adjacent to the corner fitting be ground to a minimum bevel of?
- 30 degrees
- 45 degrees
- 55 degrees
- 60 degrees