ICC Bolting Latest Update 2025-2026 Exam 150 Questions with 100% Verified Correct Answers Guaranteed A+

(true or false) Fastener components that accumulate rust or dirt may be incorporated

into the work if they are requalified. - CORRECT ANSWER: True - Section 2.2 -

Specification for Structural Joints

A representative sample of not fewer than "BLANK" fasteners assemblies of each combination of diameter, length, and grade of bolt used in the work shall be checked at the site of installation to verify that the pretensioning method develops a pretension that is equal to or greater "BLANK" times than specified. - CORRECT ANSWER: three and 1.05

A tension calibrator shall be used where bolts are to be installed in: - CORRECT

ANSWER: Pretensioned joints

According to the AISC Steel Construction Manual, the grout used between the column base plate and the foundation must be: - CORRECT ANSWER: High-strength non- shrink

According to the AISC Steel Construction Manual, the minimum washer thickness for a base plate anchor rod 1 inch diameter is "BLANK" inches. - CORRECT ANSWER: ⅜ inch - Table 14-2, Part 14, AISC Steel Construction Manual

According to the AISC Steel Construction Manual, the recommended maximum size of anchor rod hole in a base plate for a 1 inch diameter anchor rod is "BLANK" inches. -

CORRECT ANSWER: 1-13/16 inches - Table 14-2, Part 14, AISC Steel Construction

Manual

  • / 3

According to the AISC Steel Construction Manual, what should be done if grouting is delayed on a base plate supported by leveling nuts until after steel erection? -

CORRECT ANSWER: Use steel shims to support the base plate. Page 14-7, Part 14,

AISC Steel Construction Manual

According to the AISC Steel Construction Manual, which of the following is not an

allowed manner for setting column base plates? - CORRECT ANSWER: treated-

hardwood shims

According to the Code of Standard Practice "BLANK" of the steel surface is required prior to shop painting. - CORRECT ANSWER: Wire Brushing - Section 6.5.2 - Code of Standard Practice for Steel Buildings and Bridges

According to the Code of Standard Practice for Steel Buildings and Bridges, "BLANK" are allowed in moderate amounts for correction of errors during steel framing erection. -

CORRECT ANSWER: drift pins, grinding, and reaming. - Section 7.14 - Code of

Standard Practice for Steel Buildings and Bridges

According to the Code of Standard Practice for Steel Buildings and Bridges, "BLANK" is the tolerance on the length of a floor beam that is less than 30 feet long. - CORRECT ANSWER: 1/16 inch - Section 6.4.1 - Code of Standard Practice for Steel Buildings and Bridges

According to the Code of Standard Practice for Steel Buildings and Bridges, how are fabricators stock steel material identified? - CORRECT ANSWER: Certified mill test reports - Section 5.2.2 - Code of Standard Practice for Steel Buildings and Bridges

According to the Code of Standard Practice for Steel Buildings and Bridges, how is steel of special material to be identified? - CORRECT ANSWER: It is marked by the supplier - Section 5.1.1, Code of Standard Practice for Steel Buildings and Bridges

According to the Code of Standard Practice for Steel Buildings and Bridges, the "BLANK" is responsible for the temporary vertical and lateral supports necessary for the 2 / 3

erection of the building framework. - CORRECT ANSWER: Steel erection contractor - Section 7.10.3 - Code of Standard Practice for Steel Buildings and Bridges

According to the Code of Standard Practice for Steel Buildings and Bridges, the "BLANK" must be approved before the fabrication of the structural steel begins. -

CORRECT ANSWER: shop and erection drawings - Section 4.4.1 - Code of Standard

Practice for Steel Buildings and Bridges

According to the Code of Standard Practice for Steel Buildings and Bridges, the number of samples required to be tested for structural steel is: - CORRECT ANSWER: The number specified by the ASTM specification - Section 5.1.1 - Code of Standard Practice for Steel Buildings and Bridges

According to the Code of Standard Practice for Steel Buildings and Bridges, the permitted method of applying shop paint is: - CORRECT ANSWER: Brushing, Rolling, or spraying - Section 6.5.3 - Code of Standard Practice for Steel Buildings and Bridges

According to the Code of Standard Practice for Steel Buildings and Bridges, what party

is to review the fabricators shop and erection drawings? - CORRECT ANSWER:

Owner's representatives for design and construction - Section 4.4 -Code of Standard Practice for Steel Buildings and Bridges

According to the Code of Standard Practice for Steel Buildings and Bridges, what types of openings for other trades are allowed to be cut in the structural steel? - CORRECT

ANSWER: Only those openings shown on the contract document drawings and

specifications. - Section 7.15 - Code of Standard Practice for Steel Buildings and Bridges

According to the Code of Standard Practice for Steel Buildings and Bridges, which party performs material tests of the structural steel for verification of material properties? -

CORRECT ANSWER: Steel supplier

  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 26, 2025
Description:

ICC Bolting Latest Update 2025-2026 Exam 150 Questions with 100% Verified Correct Answers Guaranteed A+ (true or false) Fastener components that accumulate rust or dirt may be incorporated into the...

Get this document $30.00