G2 EXAM QUIZ BANK UPDATE QUESTIONS

Study Guides Aug 2, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

  • | Page

G2 EXAM QUIZ BANK UPDATE) QUESTIONS

AND VERIFIED ANSWERS| 100% CORRECT|

GRADE A

The type of heat exchanger associated with a forced air combination system is

ANSWER: A water to air type

ANSWER: Forced air combination systems typically use water-

to-air heat exchangers to transfer heat.

How is a high limit tested on a forced warm air furnace?

ANSWER: By disconnecting the air circulating blower

ANSWER: Disconnecting the blower simulates overheating,

testing the high limit switch’s response.

  • | Page

As the gauge number of a conductor decreases, the voltage drop across the conductor

ANSWER: Decreases

ANSWER: A lower gauge number means thicker wire, reducing

resistance and voltage drop.

Causes cold denser outdoor air to enter through openings in the lower portion of the building envelope, where it is heated, and exit through openings in the upper building envelope where the building essentially becomes a chimney

ANSWER: Stack effect

ANSWER: Stack effect drives air movement due to temperature

and pressure differences.

  • | Page

What is used to counter balance the downstream pressure in a regulator?

ANSWER: The loading element

ANSWER: The loading element (e.g., spring or diaphragm)

adjusts to balance downstream pressure.

What is the basic sequence of operation of a control module?

ANSWER: Perform safe start check, ignite the flame, power the

gas valve, proof presence of flame, monitor flame during burner cycle

ANSWER: This sequence ensures safe and continuous burner

operation.

How is the Heat Anticipator setting determined for a Thermostat with an adjustable Anticipator?

  • | Page

ANSWER: By measuring the current drawn by the components

in the circuit being fed directly by the thermostat

ANSWER: Current measurement sets the anticipator to match

system timing.

What is true regarding perfect combustion?

ANSWER: Unable to be maintained in a combustion chamber

ANSWER: Perfect combustion is theoretical; real-world

conditions prevent it.

What is wind effect?

ANSWER: Wind can cause positive pressure on the windward

side of the building and negative pressure on the leeward side and on the sides parallel to the wind flow

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 2, 2025
Description:

G2 EXAM QUIZ BANK UPDATE) QUESTIONS AND VERIFIED ANSWERS| 100% CORRECT| GRADE A The type of heat exchanger associated with a forced air combination system is ANSWER: A water to air type ANSWER: For...

Get this document $30.00