What happens when a steam turbine reaches critical speed? - ANSWER-Turbine will vibrate violently

In a steam turbine, what is the function of the kingsbury thrust bearing - ANSWER-Maintain axial positioning of the rotor shaft

The efficiency of the refrigerant cycle is affected by the operation of the condenser.of the following. a more efficient centrifugal compressor operation results from: - ANSWER-Lowering the condensing pressure

A centrifugal water pump is considered to be fully primed when - ANSWER-The pump is full of liquid

The refrigerant unit that you have been assigned to is being taken out of service for a major repair. you have been assigned to withdraw refrigerant for storage in suitable containers. according to the new York city fire code, you must ensure that

the containers: - ANSWER-Are approved by the US department of transportation

Copper tubing refrigerant lines must be installed for a new system. it is a well known service practice that tubing collapses at bends that must be made, the refrigerant engineer should use - ANSWER-Lever type tubing bender

  • / 3

pg. 2 A reciprocating compressor is making a knocking sound during operation. if the refrigerant worn parts are not causing the knocking, what is probably the cause - ANSWER-The slugging of the liquid refrigerant

In order for a refrigerant to become superheated in a section of the lowside

refrigerant line: - ANSWER-Where no liquid refrigerant is present

All liquid has been recovered from a system to be overhauled, the system - ANSWER-Should not be opened until all vapor has been removed

When a refrigerant engineer uses a portable compressor recovery unit to remove vapor refrigerant from a refrigeration system the removal rate of the refrigerant will gradually slow down because - ANSWER-The vapor density is decreasing

You are the engineer running a 2000-ton (steam-driven turbine) centrifugal refrigeration system, a refrigeration system supplies chilled water to a college campus with multiple buildings. During the course of making your rounds, you check the 9 cell cooling tower on the roof. You note the water level in all of the cooling tower cells is very low. Which one of the following immediate action would take? - ANSWER-Add additional make up water to cooling tower

A rooftop water cooling tower is connected to a water pump in the building basement with a 12 inches diameter pipe. with the pump turn off, a pressure gauge at the pumps inlet show a pressure of 140 PSIG the height of the water column, in feet, would be closet to. - ANSWER-323

The heat removed from the refrigerant in a condenser is: - ANSWER-Sensible and

latent heat

  • / 3

pg. 3 Which of the following best describes how the cylinder unloader work? - ANSWER-Keep in the suction valve opened while the compressor is in the return stroke

In most semi hermetic compressors, the suction vapor is used to: - ANSWER-Cool

the motor

The amount of refrigerant that flows through the orifices of a economizer is

determined by the: - ANSWER-Difference between the high side and load side

pressure

The installation of an inline refrigerant cleaning system is advisable: - ANSWER- To remove impurities from the system

The type of refrigerant system that is least likely to leak refrigerant into the building space that are cooled - ANSWER-The indirect system

The suction pressure of a reciprocating compressor is 65PSIG. the discharge pressure of this compressor is 120PSIG. the atmospheric is 14.7 PSI. the

compression ratio for the given condition is closet to: - ANSWER-1.69

A super heated vapor is a ? - ANSWER-Dry vapor above the saturation temperature

A refrigerant engineer verifies that a condenser water pump is cavitating. of the following the most likely cause for this condition is: - ANSWER-A faulty cooling tower water level controller

A centrifugal water pump is known as a lift pump when the: - ANSWER-The

water supply to the pump suction inlet is below the pump level

  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 1, 2025
Description:

pg. 1 FDNY Z51 / FDNY Z-51 EXAM 2024 WITH 200+ REAL EXAM QUESTIONS AND 100% CORRECT ANSWERS GRADED A/ REAL FDNY Z51 EXAM LATEST VERSION(BRAND NEW!!) What happens when a steam turbine reaches critic...

Get this document $30.00