CSLB C10 TEST 1| 180 QUESTIONS

& ANSWERS CORRECT

100%(RATED A)

Question : What is the minimum working clearance from

an electrical panel under 600 V?

Correct answer: 36"

Question : Voltage drop in wire is a function of:

Correct answer: Wire gauge, Length of wire, Current flow

in the wire

Question : A 12-volt direct current, 13-watt fluorescent

light is controlled by a photocell. The average daily on- time is 12 hours per day. How many watt-hours are consumed by the light on an average day?

Correct answer: 156

Question : Where may you use nonmetallic-sheathed

cable?

Correct answer: inside floors and walls

  • | Page

Question : What is the maximum permitted distance

between convenience outlets in kitchens?

Correct answer: 12'

Question : The minimum permitted size fixture wire is:

Correct answer: No. 18

Question : What is an Erickson coupling used for?

Correct answer: to connect two sections of rigid conduit

when one section cannot be turned

Question : The smallest size grounding conductor

permitted for service entrance is:

Correct answer: No. 8 copper

Question : For an electric appliance with a 17.5 A load,

the overcurrent device must not exceed:

Correct answer: 25 amps

  • | Page

Question : A 5 kW appliance is used for 5 hours. At

$0.014 per kWh, the cost of running the appliance is:

Correct answer: $0.35

Question : If the plumber accidentally cuts installed wires,

to whom should you report the problem?

Correct answer: general contractor

Question : What is the maximum distance to an outlet

from any point along the wall behind a kitchen counter?

Correct answer: 24"

Question : Which of the following materials is not

corrosive?

Correct answer: enamel

Question : 65 street lights are fed by a 2275-volt series

circuit. What is the voltage across each light?

Correct answer: 35 V

  • | Page

Question : What do you not take into consideration when

doing load demand calculations?

Correct answer: small portable heating and cooling

appliances

Question : The symbol represents a:

Correct answer: relay coil

Question : A fixture that weighs more than ______ must

be supported independently of an outlet box.

Correct answer: 50 lb.

Question : After installing a new A/C how would you test

it?

Correct answer: turn on the breaker and check voltage

Question : The symptoms of shock are:

Correct answer: pale skin; sweaty; fast pulse

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 17, 2025
Description:

CSLB C10 TEST 1| 180 QUESTIONS & ANSWERS CORRECT 100%(RATED A) Question : What is the minimum working clearance from an electrical panel under 600 V? Correct answer: 36" Question : Voltage drop in ...

Get this document $30.00