Contractor's License Exam Questions and Answers 100% Pass

Question : Attachments to structural members

CORRECT ANSWER : The edges of lugs brackets, rivets

and bolt heads attached to structural members shall be permitted to extend to within 1 inch of the surface of the fire protection

Question : Parapet construction

CORRECT ANSWER : The height of the parapet shall not

be less than 30 inches above the point where the roof surface and the wall intersect.

Question : Combustible framing in fire walls

CORRECT ANSWER : Adjacent combustible members

entering into a concrete or masonry fire wall from opposite sides shall not have less than a 4 inch distance between embedded ends.

Question : Concealed sleeper spaces

CORRECT ANSWER : spaces under floors that are filled

fire resistant material; open spaces will will not exceed 100 sq feet

Question : Fire alarm height

CORRECT ANSWER : The height of the manual fire alarm

boxes shall be not less than 42 inches and not more than 48 inches

Question : Manual fire box color

CORRECT ANSWER : red

Question : Size of doors

CORRECT ANSWER : minimum clear width of 32 inches

and height no less than 80 inches

Question : Stairways width and capacity

CORRECT ANSWER : minimum width shall be not less

than 44 inches

Question : Stairway headroom

CORRECT ANSWER : stairway headroom clearance of not

less than 80 inches measured from a line connecting the nosings.

Question : riser height

CORRECT ANSWER : 4-7

Question : tread depth

CORRECT ANSWER : 11 inches minimum

Question : Dimensional uniformity (stairs)

CORRECT ANSWER : the difference between the greatest

and the smallest stair shall not exceed 3/8 inch

Question : Handrails

CORRECT ANSWER : Stairways shall have handrails on

each side and adequate in length

Question : Handrail height

CORRECT ANSWER: 34-38 inches

Question : HANDRAIL CLEARANCE FROM THE WALLS

CORRECT ANSWER : 1.5 inches

Question : guards

CORRECT ANSWER : Guards shall be located along open-

sided walking surfaces more than 30 inches off the ground

Question : Guard Height

CORRECT ANSWER : shall not be less than 42 inches

Question : Guard opening limitations

CORRECT ANSWER : no openings large enough to allow a

  • inch ball to pass through if so a curb is required

Question : Emergency Escape and Rescue Opening

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 18, 2025
Description:

Contractor's License Exam Questions and Answers 100% Pass Question : Attachments to structural members CORRECT ANSWER : The edges of lugs brackets, rivets and bolt heads attached to structural memb...

Get this document $30.00