  • In BAEP's, cochlear nucleus lesion causes?

Answer: Increased III-V, increased I-V

  • Which modality is most useful in monitoring the integrity of the corticospinal tracts during
  • resection of an intramedullary spinal cord tumor?

Answer: - D-Waves

  • The stimulus used in a brainstem auditory evoked potential study is a click with a peak
  • acoustic power in the range of

Answer: 2000 to 4000Hz

  • Which of the following tibial nerve responses is not a near field response?-

Answer: N31

  • How many amperes of current will flow in a circuit containing a 2V battery and 10 ohms of
  • resistance?

Answer: 0.2 amps

6. In BAEP's blood, betadine or irrigation fluid in tubing causes:

Answer: Increase in absolute latency, normal inter-peak latencies

  • In averaging, the period of analysis is called or .

Answer: Epoch, sweep length

  • While monitoring BAEP, there was a prolongation of wave I through V by more than 2
  • msec. Which of the following choices is NOT a possible cause?-

Answer: Increase of isoflurane anesthesia

  • Involuntary movement

Answer: Ataxia

10. Smaller surface of stimulating electrodes:

Answer: Higher Current Density

  • During posterior fossa surgery, when BAEPs are used for monitoring brain- stem function, it

is most important to:

Answer: Stimulate and record from the contralateral side

  • P100 of a VEP will have the highest amplitude in which derivation? 1 / 2

Answer: MO-Fz

  • Cranial nerve VII must be monitored concurrently with BAERs.

Answer: True

14. Nerves of the body, such as median, ulnar, and femoral are formed from the:

Answer: Dorsal and ventral rami

15. Upper motor neuron extends from:

Answer: Precentral gyrus to ventral horn

  • Increasing the stimulus rate of BAEPs

Answer: Decreases amplitude and increases latency

  • Which of the following is the normal interocular latency difference of P100?

Answer: Less than 15 msec

  • An amplifier sensitivity setting that produces a vertical deflection of 1cm with an input of

10mV is:

Answer: 1mV/mm

  • When identifying wave IV and V of a BAEP, which of the following would be most
  • helpful?

Answer: Cz-Contra ear montage

  • The maximum leakage current should be

Answer: 100 uA

  • Wave V is usually the most prominent peak after

Answer: 5.5 msec

  • Which of the following montages will best demonstrate waves I through V of the BAEP?

Answer: Cz-ipsilateral ear

  • P13 Generator

Answer: Spinomedullary junction

  • An electrode recording from Erb's point is placed

Answer: 2-3 cm above the clavicle

25. In BAEP's, perforated or hardened tympanic membrane causes:

Answer: Increase in absolute latency, normal inter-peak latencies

  • / 2

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 17, 2025
Description:

CNIM TEST 2024 New Full Questions and Answers ( Included ) 100% Correct 1. In BAEP's, cochlear nucleus lesion causes? Answer: Increased III-V, increased I-V 2. Which modality is most useful in moni...

Get this document $30.00