CCI CRAT Exam Practice Test 2 100

Study Guides Aug 18, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

CCI CRAT Exam Practice Test 2 100% correct

Question : When the technician is performing a 12 lead EKG,

how many electrodes are used to record the 12 views of the heart?

Correct answer: 10

When the technician is performing a 12 lead EKG, there would be 10 electrodes used to record the 12 leads or views of the heart. Twelve leads doesn't necessarily mean 12 electrodes.

Question : Segments and waveforms on an ECG would

include all but which of the following?

Correct answer: TB wave

Segments and waveforms on an ECG would include:PR

interval QRS complexQT intervalP waveST segmentU waveT wave

Question : The parasympathetic nervous system would do

which of the following?

Correct answer: All of the above

The parasympathetic nervous system would:Slow the patient's

heart rateEnhance digestionDecrease the patient's blood pressureIs mediated by acetylcholine

Question : If the contact on a electrode is not conducting well

or the placement is wrong, which of the following could occur?

Correct answer: Wandering baseline

If the contact on a electrode is not conducting well or the placement is wrong, it could cause a wandering baseline. The wandering baseline can also be caused by chest wall during respiration.

Question : When interpreting a cardiac rhythm strip, all of the

following would be considered steps except?

Correct answer: Determining the age of the patient

When interpreting a cardiac rhythm strip, there are 5 steps:

Examine all of the components and the shape of the waveforms.Check the position of the P wave.Determine if all the complexes are alike.Determine the rate of the rhythm and if it is normal or abnormal.Evaluate if the rhythm is regular or irregular.

Question : Which of the following is the typical maximum

length for a PR interval?

Correct answer: 0.20 seconds is the typical maximum length

for PR interval. This of course can vary with heart rate from 0.12 to 0.20 seconds.

Question : Which of the following artifact results from

electrical equipment, mobile telephones, and electrical power lines?

Correct answer: Electromagnetic interference, also known as

60 cycle interference, is artifact caused by electrical equipment, mobile telephones, and electrical power lines. To minimize 60 cycle interference (or 60 Hz pickup), the technician should set the diagnostic mode of the 12-lead electrocardiogram monitor to 0.05-40 Hz. With the low frequency/high pass filter set to 0.05 the monitor should produce accurate ST-segments.

Question : In the 1,500 method for calculating atrial rate, the

technician should count which of the following?

Correct answer: Squares between two consecutive P waves

To calculate atrial rate with the 1,500 method, the technician would tally the little squares between two consecutive P waves and then divide 1,500 by that amount. There are 1,500 small squares in a one minute rhythm strip.

Question : Which of the following would not be considered a

patient area of education?

Correct answer: Providing financial counseling

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 18, 2025
Description:

CCI CRAT Exam Practice Test 2 100% correct Question : When the technician is performing a 12 lead EKG, how many electrodes are used to record the 12 views of the heart? Correct answer: 10 When the ...

Get this document $30.00