CAOHC Exam Prep Latest Update 2024-2025 450+ Questions and 100% Verified Correct Answers Guaranteed A+ At First Attempt

"hearing levels" used by audiometers are also known as "sound pressure levels": -

CORRECT ANSWER: false

29 CFR 1910.95 is an example of a standard, not a regulation: - CORRECT ANSWER: false

a sound level meter is used to calculate sound wave frequency: - CORRECT ANSWER: false

acoustic neuromas can manifest as an asymmetric or unilateral hearing loss: -

CORRECT ANSWER: true

administrative controls to limit noise exposure to include: - CORRECT ANSWER: limiting the time a worker spends at a noise source

after rolling down a foam plug, you should wait 30 seconds before insertion: -

CORRECT ANSWER: false

age correction values are determined by: - CORRECT ANSWER: a. use of a binomial equation published in Appendix D of the regulations

  • CONSULTING TABLES PUBLISHED IN APPENDIX F OF THE REGULATIONS

ambient noise above permissible levels during hearing testing may: - CORRECT

ANSWER: a. increase the number of STS

  • alter test thresholds
  • distract test subjects
  • ALL OF THE ABOVE
  • none of the above

an accurate STS calculation must not include age correction: - CORRECT ANSWER: false

asymmetric hearing loss is when the loss in both ears is approximately equal: -

CORRECT ANSWER: false

audiometric testing is also known as a hearing screening: - CORRECT ANSWER: false

banded earplugs are also known as "canal caps" - CORRECT ANSWER: false

  • / 4

banded earplugs are designed to be disposed of after one use: - CORRECT ANSWER: false

baselines may never be revised: - CORRECT ANSWER: false

compliance with OSHA regulations implies that NIHL prevention best practices have been followed: - CORRECT ANSWER: false

conductive hearing loss is due to issues with the inner ear: - CORRECT ANSWER: false

continuous noise is defined as noise lasting longer than: - CORRECT ANSWER: a. 1

SECOND

  • 2 seconds
  • 3 seconds
  • 5 seconds
  • none of the above

conventional earplugs typically reduce high frequency noise more than low-frequency noise: - CORRECT ANSWER: true

daily biological checks should include a listening check of the audiometer: - CORRECT

ANSWER: true

decibel is a unit of: - CORRECT ANSWER: sound intensity

during acoustic calibration, no adjustments are made to an audiometer: - CORRECT

ANSWER: true

during audiometry, the workers should be seated so they may see the OHC's activities:

- CORRECT ANSWER: false

each ear may have a different baseline test: - CORRECT ANSWER: true

earmuffs should be cleaned with solvents regularly to prevent particulate build-up: -

CORRECT ANSWER: false

engineering controls to limit noise exposure include which of the following? - CORRECT

ANSWER: a. lubricating machinery

  • enclosing the noise source
  • changing to lower-noise tools and machinery
  • erecting barriers between the noise source and worker
  • ALL OF THE ABOVE

flat attenuation earplugs allow for better speech recognition than traditional earplugs: -

CORRECT ANSWER: false 2 / 4

flat hearing loss can be caused by which of the following? - CORRECT ANSWER: a.

equipment malfunction

  • worker response error
  • intentionally not responding to tones to simulate a loss
  • conductive pathology
  • ALL OF THE ABOVE

for best results, worker training procedures should be evaluated for effectiveness and revised according to findings: - CORRECT ANSWER: true

for how many years does OSHA require audiogram records be kept? - CORRECT

ANSWER: a. 1 year

  • 2 years
  • 5 years
  • DURATION OF EMPLOYMENT
  • OSHA does not specify the time

for otoscopy the OHC should select the largest speculum that will fit in the ear canal: -

CORRECT ANSWER: true

FRA requires worker training within 180 days of enrollment in a hearing conservation program: - CORRECT ANSWER: true

FRA requires written notification of an STS within: - CORRECT ANSWER: 30 days

functional hearing loss is also known as pseudohypacusis: - CORRECT ANSWER: true

group worker training is proven to be more effective than one-on-one training: -

CORRECT ANSWER: false

hearing aids should be removed prior to audiometric testing: - CORRECT ANSWER: true

hearing loss from non-occupational sources is called "sociocusis": - CORRECT

ANSWER: true

hearing protection devices are worn to: - CORRECT ANSWER: a. reduce the risk of ear infection

  • eliminate all noise except in the range of speech frequencies
  • REDUCE THE CHANCE OF NIHL
  • all of the above

hearing tests do not have to be conducted in a sound booth as long as maximum allowable ambient noise levels aren't exceeded: - CORRECT ANSWER: true

  • / 4

hertz is a unit of: - CORRECT ANSWER: sound frequency

how many years does OSHA require noise exposure records be kept? - CORRECT

ANSWER: a. 1 year

  • 2 YEARS
  • 5 years
  • duration of employment
  • OSHA does not specify the time

if a worker fails to respond to soft tones, whisper audiometry should be employed: -

CORRECT ANSWER: false

if daily calibration threshold is off by more than 5 dB, the audiometer must be acoustically calibrated: - CORRECT ANSWER: true

if NIOSH's recommended 3 dB exchange rate is used, which of the following equals a

100% noise dose? - CORRECT ANSWER: a. 4 hours in 87 dB

  • 4 hours in 90 dB
  • 4 HOURS IN 93 dB
  • 8 hours in 87 dB
  • 8 hours in 93 dB

if the diaphragm of the headphones is not positioned over the ear canal, response to high frequency may be affected: - CORRECT ANSWER: true

impulse noise is defined as noise lasting less than: - CORRECT ANSWER: a. 1

SECOND

  • 2 seconds
  • 3 seconds
  • 5 seconds
  • none of the above

in addition to the OSHA requirements, the FRA requires what datum on audiograms? -

CORRECT ANSWER: a. worker gender

  • AUDIOMETER MODEL
  • examiner CAOHC number
  • HCP professional supervisor name
  • audiometric room certification date

in addition to the OSHA requirements, the FRA requires which of the following for

worker training? - CORRECT ANSWER: a. explanation of noise operational controls

  • purpose of noise monitoring
  • expected range of workplace noise exposure levels
  • employee rights and responsibilities
  • ALL OF THE ABOVE
  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 17, 2025
Description:

CAOHC Exam Prep Latest Update 2024-2025 450+ Questions and 100% Verified Correct Answers Guaranteed A+ At First Attempt "hearing levels" used by audiometers are also known as "sound pressure levels...

Get this document $30.00