C-39 ROOFING TRADE TEST 1 AND TEST 2 ALL

Study Guides Aug 2, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

  • | Page

C-39 ROOFING TRADE TEST 1 AND TEST 2 | ALL

QUESTIONS AND CORRECT ANSWERS |

GRADED A+ | VERIFIED ANSWERS | LATEST

VERSIONS 2025

1. Composition flashing (base flashing) should be fastened with:

ANSWER: One-inch solid cap-head nails or nails driven

through tin disks

2. Pitch pockets or pitch boxes:

ANSWER: Are not recommended because they require

extensive maintenance

  • Reinforced concrete can be used as a structural deck. Which
  • of the following is a correct statement?

ANSWER: Some moisture will remain in concrete decks even

after the surface is dry

  • Roofing insulation and membranes must be protected from
  • latent moisture in concrete decks. In northern climates, this is

usually accomplished with:

ANSWER: A vapor retarder or a venting sheet

  • | Page
  • Steel decks should be at least _______ or heavier.

ANSWER: 22g

  • Insulation applied to steel roof decks before the roof

membrane is installed should be applied:

ANSWER: In two separate layers where insulation thickness

permits

7. The top flanges of a steel roof deck should be installed:

ANSWER: Perpendicular to the roof slope

8. The maximum deflection allowed for a steel deck is:

ANSWER: 1/4" per 100 feet

  • If the steel decks must be spot-welded to structural steel,
  • puddle welds _______ or larger in diameter are recommended.They should be made on washers and spaced at least _______ on center.

ANSWER: 1/2 inches ... 12 inches

  • | Page
  • If thermosetting insulation is used over structural decks, the

density should be:

ANSWER: 18 to 22 pounds per cubic foot

  • The correct density for thermosetting insulation is

accomplished by:

ANSWER: Compacting

  • Thermosetting insulation is compacted in two layers if the

total thickness is greater than:

ANSWER: 6 inches

  • Thermosetting insulative fills must be protected from latent
  • moisture in roof decks. Which of the following procedures is recommended?

ANSWER: Install base-ply vapor barrier and install wood

nailers at all perimeters and install wood nailers at all roof projections

  • What type of roof is recommended over thermosetting
  • insulative fills?

  • | Page

ANSWER: Aggregate

  • A span rating of _______ means that a plywood panel may
  • be used for roof decking over supports spaced 32 inches o.c. or for subflooring over supports spaced 16 inches o.c.

ANSWER: 32/16

  • On plywood decks not covered with insulation, a base ply
  • should be _______ to serve as the base ply of the roof membrane.

ANSWER: Attached with annular-threaded nails

  • The choice of membrane type for a roof is frequently

determined by:

ANSWER: Geographical location and climate

  • Technical information useful in the selection of roof

membranes is provided by the:

ANSWER: National Bureau of Standards

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 2, 2025
Description:

C-39 ROOFING TRADE TEST 1 AND TEST 2 | ALL QUESTIONS AND CORRECT ANSWERS | GRADED A+ | VERIFIED ANSWERS | LATEST VERSIONS 2025 1. Composition flashing (base flashing) should be fastened with: ANSWE...

Get this document $30.00