BACKFLOW PREVENTION ASSEMBLY
TESTER CERTIFICATION EXAM 2025 -
LATEST ACTUAL EXAM QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED
ANSWERS) |ALREADY GRADED A+
To avoid creating water hammer, when returning a backflow prevention assembly to service the tester should
- Slowly pressurize the assembly and then slowly pressurize the
- Slowly pressurize the downstream piping and then slowly
- Close shut-off valve #2 after opening shut-off valve #1
- Close shut-off valve #1 after opening shut-off valve #2 Correct
downstream piping
pressurize the assembly
Answer A
In a backsiphonage condition, the check valves of a double check assembly will be
- 1st check closed and 2nd check open
- 1st check open and 2nd check closed
- 1st check open and 2nd check open
- 1st check closed and 2nd check closed Correct Answer D
How many test cocks must an approved double check valve assembly have?
- 3
- 4
- 5
- 8 Correct Answer B
A leaking check valve #2 of a reduced pressure assembly and backpressure may cause 1 / 3
- Pressure regulator damage
- Disc compression
- Relief valve discharge
- Check valve #1 to open Correct Answer C
What could be the problem if the relief valve of a reduced pressure assembly discharges intermittently?
- Shut-off valve #1 is closed with backpressure
- Shut-off valve #1 is open with backpressure
- Large pressure fluctuations
- Assembly is improperly sized Correct Answer C
Which of the following backflow assemblies contains an independently operating internally loaded check valve and an independently operating loaded air inlet valve located on the discharge side of the check?
- Atmospheric vacuum breaker
- Double check valve assembly
- Pressure vacuum breaker assembly
- Reduced pressure backflow assembly Correct Answer C
Which of the following backflow assemblies is allowable for use against a contaminant when the backflow could be caused by backpressure?
- Atmospheric vacuum breaker
- Double check valve assembly
- Pressure vacuum breaker assembly
- Reduced pressure backflow assembly Correct Answer D
While testing check valve #2 of a reduced pressure backflow assembly under backpressure, what would be observed if the second check valve was fouled? (positive differential does not mean it passes)
- No differential (0 psi)on the test kit and no discharge from the
relief valve 2 / 3
- No differential (0 psi) on the test kit and discharge from the
- Differential (±5 psi) on the test kit and no discharge from the
- Differential (±5 psi)on the test kit and discharge from the relief
relief valve
relief valve
valve Correct Answer D - failed check valves cause water to flow to buffer zone and push the relief open, the reading can be positive but still under 5 and fail
What could be determined while testing check valve #1 of a double check valve assembly if the gauge reads 0.7 psid?
- Check valve #1 is defective
- Check valve #2 is defective
- Shut-off valve #1 is leaking
- Shut-off valve #2 is leaking Correct Answer A
What could a tester determine if water is observed flowing from the air inlet of the pressure vacuum breaker prior to starting the test? (assuming proper installation)
- Shut-off valve #1 is open or leaking
- Shut-off valve #2 is open or leaking with backpressure
- Air inlet valve is defective
- Check valve is leaking Correct Answer C
What may be determined when testing the air inlet valve of an approved pressure vacuum breaker if the air inlet valve is observed to open after closing shut-off valve #1?
- Air inlet valve is defective
- Shut-off valve #1 is leaking
- Shut-off valve #2 is leaking with flow downstream
- Shut-off valve #2 is leaking with backpressure Correct Answer
- / 3
C