BACKFLOW PREVENTION ASSEMBLY

TESTER CERTIFICATION EXAM 2025 -

LATEST ACTUAL EXAM QUESTIONS AND

CORRECT DETAILED ANSWERS (VERIFIED

ANSWERS) |ALREADY GRADED A+

To avoid creating water hammer, when returning a backflow prevention assembly to service the tester should

  • Slowly pressurize the assembly and then slowly pressurize the
  • downstream piping

  • Slowly pressurize the downstream piping and then slowly
  • pressurize the assembly

  • Close shut-off valve #2 after opening shut-off valve #1
  • Close shut-off valve #1 after opening shut-off valve #2 Correct
  • Answer A

In a backsiphonage condition, the check valves of a double check assembly will be

  • 1st check closed and 2nd check open
  • 1st check open and 2nd check closed
  • 1st check open and 2nd check open
  • 1st check closed and 2nd check closed Correct Answer D

How many test cocks must an approved double check valve assembly have?

  • 3
  • 4
  • 5
  • 8 Correct Answer B

A leaking check valve #2 of a reduced pressure assembly and backpressure may cause 1 / 3

  • Pressure regulator damage
  • Disc compression
  • Relief valve discharge
  • Check valve #1 to open Correct Answer C

What could be the problem if the relief valve of a reduced pressure assembly discharges intermittently?

  • Shut-off valve #1 is closed with backpressure
  • Shut-off valve #1 is open with backpressure
  • Large pressure fluctuations
  • Assembly is improperly sized Correct Answer C

Which of the following backflow assemblies contains an independently operating internally loaded check valve and an independently operating loaded air inlet valve located on the discharge side of the check?

  • Atmospheric vacuum breaker
  • Double check valve assembly
  • Pressure vacuum breaker assembly
  • Reduced pressure backflow assembly Correct Answer C

Which of the following backflow assemblies is allowable for use against a contaminant when the backflow could be caused by backpressure?

  • Atmospheric vacuum breaker
  • Double check valve assembly
  • Pressure vacuum breaker assembly
  • Reduced pressure backflow assembly Correct Answer D

While testing check valve #2 of a reduced pressure backflow assembly under backpressure, what would be observed if the second check valve was fouled? (positive differential does not mean it passes)

  • No differential (0 psi)on the test kit and no discharge from the
  • relief valve 2 / 3

  • No differential (0 psi) on the test kit and discharge from the
  • relief valve

  • Differential (±5 psi) on the test kit and no discharge from the
  • relief valve

  • Differential (±5 psi)on the test kit and discharge from the relief
  • valve Correct Answer D - failed check valves cause water to flow to buffer zone and push the relief open, the reading can be positive but still under 5 and fail

What could be determined while testing check valve #1 of a double check valve assembly if the gauge reads 0.7 psid?

  • Check valve #1 is defective
  • Check valve #2 is defective
  • Shut-off valve #1 is leaking
  • Shut-off valve #2 is leaking Correct Answer A

What could a tester determine if water is observed flowing from the air inlet of the pressure vacuum breaker prior to starting the test? (assuming proper installation)

  • Shut-off valve #1 is open or leaking
  • Shut-off valve #2 is open or leaking with backpressure
  • Air inlet valve is defective
  • Check valve is leaking Correct Answer C

What may be determined when testing the air inlet valve of an approved pressure vacuum breaker if the air inlet valve is observed to open after closing shut-off valve #1?

  • Air inlet valve is defective
  • Shut-off valve #1 is leaking
  • Shut-off valve #2 is leaking with flow downstream
  • Shut-off valve #2 is leaking with backpressure Correct Answer
  • C

  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: EXAM ELABORATIONS
Added: Sep 7, 2025
Description:

BACKFLOW PREVENTION ASSEMBLY TESTER CERTIFICATION EXAM 2025 - LATEST ACTUAL EXAM QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+ To avoid creating water hammer, when re...

Get this document $30.00