ARRT PRACTICE EXAM
COMPLETE ANSWERS 100% CORRECT (LATEST 2024 / 2025 )
1. Effective dose may be found in what published material?: NCRP reports
- The smallest particle of an element that retains the characteristics of the element is an?:
atom
3. Atomic mass =: number of protons = number of neutrons
4. Electronic timers used in xray equipment allow for exposure times of?: -
1/1000 seconds
- To ensure consistency of radiographic quality from one exposure to the next, what device
may be used?: AEC
- Devices in the x-ray circuit that operate on the principle of mutual induction are called?:
Transformers
- The high voltage section of the x-ray circuit makes use of what type of transformer?: Step-
- Xray tube NEEDS what type of current?: DC direct current rectifier changes AC to DC
up
9. The result of thermionic emission is?: Electron cloud
10. Focusing cup is located at the?: Cathode
- Outer shell filling holes in the K-shell is?: Characteristic K-shell holds 2 elections
12. Digital fluro should be viewed on?: High resolution monitor
- A primary advantage of digital fluro is?: Post processing and manipulation of the image
- Algorithm is?: A mathematical formula used to reconstruct the image in digital imaging.
- In CR each pixel corresponds to a shade of gray representing an area in the patient known
as a?: voxel
- Lightness and darkness maybe be adjusted by?: Adjusting WINDOW LEVEL (brightness)
Window width (contrast or gray level)
17. The window level in CR is the?: Midpoint of densities
18. The amount of receptor exposure is controlled PRIMARILY by?: mAs
19. The visible image may also be called the?: Manifest image
- The rule or law that governs changing technique using kVp is the?: 15% rule 1 / 2
- If SID is halved, what may be said about receptor exposure?: exposure is quadrupled
22. CR cassettes should be erased at least?: Every 48 hours
23. The equation H/D (height/distance) refers to what?: grid ratio
24. If the exposure field is not accurately recognized the histogram?: Widens
- Edge enhancement provides?: Artificial increase in display CONTRAST at an edge of the
- Grid frequency is described as?: The number of lead strips per inch or centimeters
- When working with CR and DR one must be aware that their response to scatter radiation
image.
is?: Very sensative
28. A histogram analysis error may be caused by?: Inappropriate collimation
29. Smoothing provides?: Evenness in brightness
- Consistency of image appearance is achieved through the use of?: Uniform processing codes
31. Poor spatial resolution =: Short SID Better with Long SID
- Beam restriction has the following effect on contrast?: Shorter scale of contrast
33. As kVp increases, there is an increased production of?: Short wavelengths
- The relationship between kVp and receptor exposure is:: Direct but no proportional
- Grids that have strips angled to coincide with divergence of the x-ray beam are called?:
- In digital imaging the radiographer must be aware that:: The image is determined by the
Focused grids
total exposure.
37. Units of radiation absorbed in the air?: Gya
38. The change in the x-ray beam as it travels through a patient?: attenuation
- photon tissue interaction that makes radiology possible because of it's creation of
contrast?: photoelectric interaction (fully absorbed = contrast)
40. Unit of radioactivity?: becquerel
41. unit of effective dose?: Sievert
42. Linear energy transfer ...: varies for different types of radiation
43. unit of Bq would be used in what imaging modality?: Nuclear medicine
- graphs that show relationship between radiation received and the organ- isms response?:
- Medical x-rays are examples of?: artificially produced radiation
- / 2
dose-response relationship