ACI Concrete Field Testing Technician- Grade I questions with correct answers

Question : The sensor of the temperature measuring device

shall be submerged a minimum of _____ in. [_____mm] into the freshly mixed concrete.

Correct answer: 3 in. [75 mm]

Question : The temperature measuring device shall have a

capacity of measuring temperature of freshly mixed concrete to +- _____ degrees F [+- _____ C] throughout a range of

_____.

Correct answer: 1 degree F [0.5 C], 30 degrees F to 120 F [0

C to 50 C]

Question : The temperature measuring device shall be

calibrated _____, or whenever there is a question of _____.

Correct answer: Annually, accuracy

Question : The temperature of concrete may be measured in a

wheelbarrow. True or False?

Correct answer: True

Question : The temperature of concrete may be measured in a

wall form. True of False

Correct answer: True

Question : A composite sample of concrete is required even if

the only purpose for obtaining the sample is to determine temperature. True of False?

Correct answer: False

Question : What must be done to the sample container prior to

sampling the concrete?

Correct answer: Dampen (with water)

Question : What must be done to the concrete surrounding the

temperature measuring device after the device is submerged in the fresh concrete.

Correct answer: Gently press the concrete around the

temperature measuring device at the surface of the concrete

Question : How long must the temperature measuring device

remain in the freshly mixed concrete?

Correct answer: At least 2 minutes but not more than 5

minutes

Question : After the temperature of the concrete is read, what

is required?

Correct answer: Reporting of temperature

Question : The temperature of concrete is reported to the

nearest _____ degrees F [_____ C]

Correct answer: 1 degree F [0.5 C]

Question : According to ASTM C1064, what is one reason to

take the temperature of concrete?

Correct answer: Verify conformance to a specified

requirement for temperature of concrete

Question : A maximum temperature of freshly mixed concrete

is specified in ASTM C1064. True of False?

Correct answer: False

Question : The sample of concrete used for temperature

determination must be rodded 25 times. True or False?

Correct answer: False

Question : Sampling by this method is required when tests are

to be made to determine _____ with specification requirements.

Correct answer: Compliance

Question : This method covers sampling from four types of

mixtures which are _____, _____, _____, and _____.

Correct answer: Stationary mixers, paving mixers, revolving

drum mixers, and open top mixers

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 2, 2025
Description:

ACI Concrete Field Testing Technician- Grade I questions with correct answers Question : The sensor of the temperature measuring device shall be submerged a minimum of _____ in. [_____mm] into the ...

Get this document $30.00