ABO EXAM PRE-TEST QUESTIONS AND

Study Guides Aug 17, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

ABO EXAM PRE-TEST QUESTIONS AND

CORRECT ANSWERS

-.75 -.50 x 120 - Correct AnswerThe patient's RX is -1.75 -.50 x 120 with a +2.00 add standard trifocal. What is the power through the intermediate.

  • -1.25 -.50 x 120
  • -.75 -.50 x 120
  • -.75 -.50 x 30
  • -1.00 -.50 x 150

-0.50 - Correct AnswerThe spherical equivalent of the lens +1.00 -3.00 x90 is

A. +0.50

B. -0.50

C. +1.25

D. -1.25

-0.50 -2.50 x115 - Correct AnswerWhich RX of the following is the same as the

following RX: -3.00 +2.50 x25

  • -3.00 +2.50 x105
  • -0.50 -2.50 x115
  • +0.50 +2.50 x115
  • +3.00 -0.50 x105

-2.00 -1.00 x90 - Correct AnswerThe optician has just neutralized an unknow power lens with test lenses. The test lens used to neutralize the power in the vertical is a plus 2.0 and the test lens used to neutralize the power in the horizontal is a plus 3.00. What is the RX?-2.00 +0.50 x180 -2.00 -1.00 x 90 -1.50 -0.50 x 180 +1.00 +0.50 x180

-3.25 -1.50 x180 - Correct AnswerIf your lensometer reads +0.25 with no lens, a lens that measures -3.00 -1.50 x180 is actually

  • -2.75 -1.25 x180
  • -2.75 -1.50 x180
  • -3.25 -1.75 x180
  • -3.25 -1.50 x180

-9.50 - Correct AnswerA patient refracted at 15mm is prescribed a -10.00 shpere. The dispenser finds that the actual fitting distance will be at 10mm. What should the compensated lens power be?

A. -9.50

B. -9.75

C. -10.75

D. -10.50 1 / 3

+1.00 -1.25 - Correct AnswerIn neutralizing a lens of unknown power your first reading is +1.00 and the next reading that focuses the cylinder target is -0.25.What is the RX?

A. +1.00 -0.25

B. -0.25 +2.00

C. +1.00 -1.25

D. +0.25 +2.25

+1.75 -.25 x90 - Correct AnswerWhat would the reading RX be if the following distance

RX and bifocal addition are given:

  • +.50 -.25 x90
  • +1.75 -.25 x90
  • +2.75 -.25 x90
  • +1.25 -.25 x90

+2.00 -2.00 x90 - Correct AnswerWhich of the following has no power in the 180 degree median?

  • +2.00 -2.00 x90
  • +2.00 +2.00 x180
  • +1.00 +1.00 x135
  • +1.00 -2.00 x45

+2.50 - Correct AnswerIf the RX is OS +1.00 +3.00 x45, what would be the total power at axis power 90?

A. +1.00

B. +2.00

C. +2.25

D. +2.50

+6.12/+8.12 - Correct AnswerWhen verifying an add on on a 1 piece bifocal with a lens clock, a +2.00 add would clock ____ in the distance and ______ in the segment.

A. +6.12/+8.12

B. +4.50/-7.25

C. +4.37/+7.12

D. +3.75/+1.00

  • diapter - Correct AnswerDetermine imbalance at the reading level in the following
  • prescription (10mm reading depth) OD: -4.00 -2.00 x90 OS: -1.00 -3.00 x180

  • 4 diapters
  • 2 diapters
  • 1 diapter
  • No imbalance
  • / 3
  • diapter base in prism - Correct AnswerA +2.00 diopter lens decentered in 5mm
  • beyond the patients measured pd will create

  • 1 diapter base out prism
  • 2 diapters base out prism
  • 1 diapter base in prism
  • 2 diapters base in prism
  • diapter base out/each eye - Correct AnswerThe P.D. written on the order is
  • mistakenly noted as 70mm, when the actual measurement should be 66mm. What unwanted prism would be found if the distance prescription is O.U. +5.00 shpere.

  • 1 diapter base out/each eye
  • 1 diapter base in/each eye
  • 2 diapters out/each eye
  • 2 diapters in/each eye
  • diapter of base out prism - Correct AnswerA minus 5 diapter lens decentered in 2mm

beyond what is called for to achieve the correct PD creates:

  • 1 diapter of base in prism
  • 1 diapter of base out prism
  • 2 diapters of base in prism
  • 2 diapters of base out prism

1.00 Diapter base down - Correct AnswerThe patient is looking 10 mm below the distance optical center. What is the prismatic effect to the patient from the distance RX at that level?

  • 1.00 diapter base up
  • 1.00 diapter base down
  • 2.00 diapter base up
  • 2.00 diapter base down

1.8 diapters base in - Correct AnswerA lens which reads +3.00 -2.00 x180 is decentered in 6mm too much. How much horizontal prism is created by this error.

  • 1.8 diapters base in
  • 1.8 diapters base out
  • .6 diapters base in
  • .6 diapters base out

1.53 - Correct AnswerThe refractive index to which optical tools and gauges are calibrated is

A. 1.49

B. 1.523

C. 1.53

D. 1.56

  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 17, 2025
Description:

ABO EXAM PRE-TEST QUESTIONS AND CORRECT ANSWERS -.75 -.50 x 120 - Correct AnswerThe patient's RX is -1.75 -.50 x 120 with a +2.00 add standard trifocal. What is the power through the intermediate. ...

Get this document $30.00