2024 VTNE Radiology Test 1

Study Guides Aug 17, 2025
Loading...

Loading document viewer...

Page 0 of 0

Document Text

2024 VTNE Radiology Test 1 New Full Test | Questions and Answers ( Included ) 100% Correct

  • You have a film in front of you that has a relatively clear edge all the way around
  • the radiograph. This is because of

A:

A light leak

B:

Collimation

C:

Not being developed or fixed

D:

Overexposure to radiation

Answer: Collimation

  • A veterinarian is performing a radiographic survey of a cat's skull to eval- uate the
  • trabecular bone in the nasal cavity for a nasal tumor (producing asymmetry).Knowing that ultra fine detail is needed, which of the following equipment would best allow for a diagnostic study?

A:

Fast screen and film combination

B:

Slow screen and film combination

C:

Fast screen and slow film combination

D:

Slow screen and fast film combination

Answer: Slow screen and film combination

  • What is the term used to describe the tube-to-film distance?

A:

Focal-film distance

  • / 3

B:

Focal-object distance

C:

Focal-skin distance

D:

Focal spot

Answer: Focal-film distance

4. A grid with a ratio of 10:1 absorbs

A:

Less scatter radiation and requires less exposure factors than a 5:1 grid

B:

Less scatter radiation and requires greater exposure factors than a 5:1 grid

C:

More scatter radiation and requires greater exposure factors than a 5:1 grid

D:

More scatter radiation and requires less exposure factors than a 5:1 grid

Answer: More scatter radiation and requires greater exposure factors than a 5:1 grid

  • A tabletop (nongrid) technique is used to radiograph the

A:

Thorax

B:

Abdomen

C:

Extremity

D:

Pelvis

Answer: Extremity

  • / 3
  • Where is the most effective place to wear an x-ray film badge?

A:

On the belt

B:

On the shirt collar outside of the apron

C:

On the hand

D:

In the area of anatomic risk

Answer: On the shirt collar outside of the apron

  • The target of an x-ray machine is a/an

A:

Tungsten coil that emits electrons when heated

B:

Small depression where the filament is placed

C:

Area of the anode struck by electrons during an exposure

D:

Positive electrode

Answer: Area of the anode struck by electrons during an exposure

  • The maximum permissible dose (MPD) for whole-body radiation per year in
  • sieverts is

A:

0.05

B:

0.50

C:

5.0

  • / 3

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 17, 2025
Description:

2024 VTNE Radiology Test 1 New Full Test | Questions and Answers ( Included ) 100% Correct 1. You have a film in front of you that has a relatively clear edge all the way around the radiograph. Thi...

Get this document $30.00