pg. 1

2024 ABRET EEG EXAM TEST BANK WITH 500

REAL EXAM QUESTIONS AND CORRECT

ANSWERS ALREADY GRADED A+/ ABRET EEG

EXAM PREP LATEST 2024/2025 (QUESTIONS

AND 100% CORRECT ANSWERS)

An EEG record has three per second spike/wave discharges. Both the spike and the slow wave have voltages of 100 µV. If this discharge is recorded with a low frequency filter of 5 Hz and a sensitivity of 10 µV/mm, what would be the deflection of the spike and the wave?

  • spike 10 mm, wave 6 mm
  • spike 6 mm, wave 10 mm
  • spike 10mm, wave 10 mm
  • spike 6 mm, wave 6 mm - ANSWER-spike 10 mm, wave 6 mm

A high frequency setting of 35 Hz would attenuate 50 Hz muscle activity by approximately what percentage?

  • 10%
  • 20%
  • 40%
  • 100% - ANSWER-40%

A small fluctuating output recorded by the EEG instrument even when there is no input signal is called ____.

  • output voltage
  • linear distortion 1 / 4

pg. 2

  • 60 Hz interference
  • noise - ANSWER-noise

The EEG amplifier is designed so that when input 1 is more negative than input 2, the deflection will be ____.

  • downward
  • upward
  • absent
  • sinusoidal - ANSWER-upward

Common Mode Rejection is ____.

  • the ability of an amplifier to cancel out ECG artifact
  • the characteristic of an amplifier that rejects external interference
  • is dependent on the sampling rate
  • controlled by the 60-cycle notch filter - ANSWER-the characteristic of an
  • amplifier that rejects external interference

Which of the following is most attenuated by a low frequency filter of 1 Hz?

  • 0.5 Hz
  • 5.0 Hz
  • 10.0 Hz
  • 0.1 Hz - ANSWER-0.1 Hz

According to ACNS Guidelines, Recording Clinical EEG on Digital Media requires monitors to have _____.

  • Between 25 and 35 mm/second horizontal scaling and a maximum of 1000 data
  • points/second to accurately display EEG on the monitor screen. 2 / 4

pg. 3

  • Between 25 and 35 mm/second horizontal scaling and a minimum of 100 data
  • points /second to accurately display EEG on the monitor screen.

  • Between 25 and 35 mm/second horizontal scaling and a maximum of 100 data
  • points/second to accurately display EEG on the monitor screen.

  • Between 25 and 35 mm/second horizontal scaling and a minimum of 1000 data
  • points/second to accurately display EEG on the monitor screen. - ANSWER- Between 25 and 35 mm/second horizontal scaling and a minimum of 100 data points /second to accurately display EEG on the monitor screen.

The filters creating a very narrow band pass that should rarely be used clinically are _____.

  • LF 5.0 Hz and HF 70 Hz
  • LF 5.0 Hz and HF 15 Hz
  • LF 0.1 Hz and HF 70 Hz
  • LF 0.1 Hz and HF 15 Hz - ANSWER-LF 5.0 Hz and HF 15 Hz

The basic unit for measuring current flow is____.a.atomic weight b.Coulomb c.Volt d.Ampere - ANSWER-Ampere

The basic unit of resistance is____.a.Ohm b.Coulomb c.Ampere d.Volt - ANSWER-Ohm 3 / 4

pg. 4

Which of the following is not a valid expression of Ohm's law?(in this equation E (electromotive force) is the dame as V (Voltage)

  • R = E I or (R = V I)
  • E = I R or (V = I R)
  • I = E / R or (I = V/R)
  • R = E / I or (R = V/ I) - ANSWER-R = E I or (R = V I)

Which of the following is not a unit for measuring alternating frequencies?

  • Cycles per second
  • Volts
  • Hertz
  • Kilocycles - ANSWER-Volts

Which of the following describes the action of a capacitor?

  • opposes changes in current flow
  • converts alternating current to direct current
  • creates a direct current resistance
  • stores energy - ANSWER-stores energy

A circuit that allows some frequencies to pass through it, while others are blocked is a ____.

  • resistor
  • transistor
  • filter
  • reactor - ANSWER-filter
  • / 4

Download Document

Buy This Document

$30.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Study Guides
Added: Aug 1, 2025
Description:

pg. 1 2024 ABRET EEG EXAM TEST BANK WITH 500 REAL EXAM QUESTIONS AND CORRECT ANSWERS ALREADY GRADED A+/ ABRET EEG EXAM PREP LATEST (QUESTIONS AND 100% CORRECT ANSWERS) An EEG record has three per s...

Get this document $30.00